Chapter 6 Control Modes of Operation
|
ASDA-B Series
Revision January, 2009
6-9
6.3 Speed
Control
Mode
The speed control mode (S or Sz) is usually used on the applications of precision speed control, such as
CNC machine, etc. ASDA-B series servo drive supports two kinds of command sources in speed control
mode. One is external analog signal and the other is internal parameter. The external analog signal is from
external voltage input and it can control the speed of servo motor. There are two usage of internal parameter,
one is set different speed command in three speed control parameters before operation and then using SP0
and SP1 of CN1 DI signal perform switching. The other usage is using serial communication to change the
setting value of parameter.
Beside, in order to make the speed command switch more smoothly, ASDA-B series servo drive also
provides complete S-curve profile for speed control mode. For the closed-loop speed control, ASDA-B series
servo drive provides gain adjustment function and an integrated PI or PDFF controller. Besides, two modes
of tuning technology (Manual/Auto) are also provided for the users to select (parameter P2-32).
6.3.1 Command Source of Speed Control Mode
Speed command Sources:
1) External analog signal: External analog voltage input, -10V to +10V
2) Internal parameter: P1-09 to P1-11
CN1 DI signal
Speed
Command
SPD1
SPD0
Command Source
Content
Range
S
External analog
signal
Voltage between V-
REF-GND
+/-10 V
S1 0
0
Mode
Sz
N/A
Speed command is
0
0
S2 0
1
P1-09
+/-5000
rpm
S3 1
0
P1-10
+/-5000
rpm
S4 1
1
Internal parameter
P1-11 +/-5000
rpm
Table 6.C
State of SPD0~1: 0: indicates OFF (Normally Open); 1: indicates ON (Normally Closed)
When SPD0 and SPD1 are both = 0 (OFF), if the control mode of operation is Sz, then the
speed command is 0. Therefore, if the users do not use analog voltage as speed command, the
users can choose Sz mode and avoid the zero point drift problem
(Note1)
of analog voltage signal.
If the speed control mode is S mode, then the command is the analog voltage between V-REF
and GND. The setting range of the input voltage is from -10V to +10V and the corresponding
motor speed is adjustable (Please see parameter P1-40).
When at least one of SPD0 and SPD1 is not 0 (OFF), the speed command is internal parameter
(P1-09 to P1-11). The command is valid (enabled) after either SPD0 or SPD1 is changed.
The speed command that is described in this section not only can be taken as speed command in
speed control mode (S or Sz mode) but also can be the speed limit input command in torque control
mode (T or Tz mode).
Содержание ASD-B0121-A
Страница 1: ......
Страница 13: ...Table of Contents ASDA B Series Revision January 2009 This page intentionally left blank...
Страница 18: ...Chapter 1 Unpacking Check and Model Explanation ASDA B Series Revision January 2009 1 5 ECMA Series Servo Motor...
Страница 53: ...Chapter 3 Connections and Wiring ASDA B Series 3 28 Revision January 2009 3 6 2 Speed Control Mode...
Страница 54: ...Chapter 3 Connections and Wiring ASDA B Series Revision January 2009 3 29 3 6 3 Torque Control Mode...
Страница 55: ...Chapter 3 Connections and Wiring ASDA B Series 3 30 Revision January 2009 This page intentionally left blank...
Страница 72: ...Chapter 4 Display and Operation ASDA B Series Revision January 2009 4 17 Figure 4 7...
Страница 75: ...Chapter 4 Display and Operation ASDA B Series 4 20 Revision January 2009 Figure 4 9...
Страница 77: ...Chapter 4 Display and Operation ASDA B Series 4 22 Revision January 2009 Figure 4 10...
Страница 79: ...Chapter 4 Display and Operation ASDA B Series 4 24 Revision January 2009 Figure 4 11...
Страница 92: ...Chapter 4 Display and Operation ASDA B Series Revision January 2009 4 37 Figure 4 21...
Страница 93: ...Chapter 4 Display and Operation ASDA B Series 4 38 Revision January 2009 This page intentionally left blank...
Страница 115: ...Chapter 5 Trial Run and Tuning Procedure ASDA B Series 5 22 Revision January 2009 This page intentionally left blank...
Страница 255: ...Chapter 9 Maintenance and Inspection ASDA B Series 9 4 Revision January 2009 This page intentionally left blank...
Страница 277: ...Chapter 11 Specifications ASDA B Series 11 10 Revision January 2009 11 4 Servo Motor Speed Torque Curves T N Curve...
Страница 291: ...Chapter 12 Application Examples ASDA B Series 12 2 Revision January 2009 PLC Program...
Страница 292: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 3...
Страница 293: ...Chapter 12 Application Examples ASDA B Series 12 4 Revision January 2009...
Страница 296: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 7 HMI DOP A HMI Program Screen Homing Operation...
Страница 297: ...Chapter 12 Application Examples ASDA B Series 12 8 Revision January 2009 Position Control 1...
Страница 298: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 9 Position Control 2...
Страница 299: ...Chapter 12 Application Examples ASDA B Series 12 10 Revision January 2009 JOG Operation...
Страница 302: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 13...
Страница 305: ...Chapter 12 Application Examples ASDA B Series 12 16 Revision January 2009 Connecting to Delta DVP 01PU...
Страница 306: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 17 Connecting to Mitsubishi FX1PG...
Страница 307: ...Chapter 12 Application Examples ASDA B Series 12 18 Revision January 2009 Connecting to Mitsubishi FX2N1PG...
Страница 308: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 19 Connecting to Mitsubishi AD75...
Страница 309: ...Chapter 12 Application Examples ASDA B Series 12 20 Revision January 2009 This page intentionally left blank...