Chapter 7 Servo Parameters
|
ASDA-B Series
7-38
Revision January, 2009
P1 - 54
PER
Positioning Completed Width
Communication Addr.: 0136H
Default: 100
Related Section:
Applicable Control Mode: P
DO TPOS(05) in Table 7.B
Unit: pulse
Range: 0 ~ 10000
Settings:
This parameter is used to set the width of pulse output range in which TPOS (positioning
completed signal) will activate. TPOS will be activated when the position error is below the
setting value of P1-54.
P1 - 55
MSPD Maximum Speed Limit
Communication Addr.: 0137H
Default: rated speed
Related Section:
Applicable Control Mode: P/S/T
Section 6.2.6
Unit: rpm
Range: 0 ~ Max. speed
Settings:
This parameter is used to set maximum motor speed. The default setting is rated speed.
Содержание ASD-B0121-A
Страница 1: ......
Страница 13: ...Table of Contents ASDA B Series Revision January 2009 This page intentionally left blank...
Страница 18: ...Chapter 1 Unpacking Check and Model Explanation ASDA B Series Revision January 2009 1 5 ECMA Series Servo Motor...
Страница 53: ...Chapter 3 Connections and Wiring ASDA B Series 3 28 Revision January 2009 3 6 2 Speed Control Mode...
Страница 54: ...Chapter 3 Connections and Wiring ASDA B Series Revision January 2009 3 29 3 6 3 Torque Control Mode...
Страница 55: ...Chapter 3 Connections and Wiring ASDA B Series 3 30 Revision January 2009 This page intentionally left blank...
Страница 72: ...Chapter 4 Display and Operation ASDA B Series Revision January 2009 4 17 Figure 4 7...
Страница 75: ...Chapter 4 Display and Operation ASDA B Series 4 20 Revision January 2009 Figure 4 9...
Страница 77: ...Chapter 4 Display and Operation ASDA B Series 4 22 Revision January 2009 Figure 4 10...
Страница 79: ...Chapter 4 Display and Operation ASDA B Series 4 24 Revision January 2009 Figure 4 11...
Страница 92: ...Chapter 4 Display and Operation ASDA B Series Revision January 2009 4 37 Figure 4 21...
Страница 93: ...Chapter 4 Display and Operation ASDA B Series 4 38 Revision January 2009 This page intentionally left blank...
Страница 115: ...Chapter 5 Trial Run and Tuning Procedure ASDA B Series 5 22 Revision January 2009 This page intentionally left blank...
Страница 255: ...Chapter 9 Maintenance and Inspection ASDA B Series 9 4 Revision January 2009 This page intentionally left blank...
Страница 277: ...Chapter 11 Specifications ASDA B Series 11 10 Revision January 2009 11 4 Servo Motor Speed Torque Curves T N Curve...
Страница 291: ...Chapter 12 Application Examples ASDA B Series 12 2 Revision January 2009 PLC Program...
Страница 292: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 3...
Страница 293: ...Chapter 12 Application Examples ASDA B Series 12 4 Revision January 2009...
Страница 296: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 7 HMI DOP A HMI Program Screen Homing Operation...
Страница 297: ...Chapter 12 Application Examples ASDA B Series 12 8 Revision January 2009 Position Control 1...
Страница 298: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 9 Position Control 2...
Страница 299: ...Chapter 12 Application Examples ASDA B Series 12 10 Revision January 2009 JOG Operation...
Страница 302: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 13...
Страница 305: ...Chapter 12 Application Examples ASDA B Series 12 16 Revision January 2009 Connecting to Delta DVP 01PU...
Страница 306: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 17 Connecting to Mitsubishi FX1PG...
Страница 307: ...Chapter 12 Application Examples ASDA B Series 12 18 Revision January 2009 Connecting to Mitsubishi FX2N1PG...
Страница 308: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 19 Connecting to Mitsubishi AD75...
Страница 309: ...Chapter 12 Application Examples ASDA B Series 12 20 Revision January 2009 This page intentionally left blank...