Chapter 5 Trial Run and Tuning Procedure
|
ASDA-B Series
Revision January 2009
5-9
5.4 Speed Trial Run without Load
Before speed trial run, fix and secure the motor as possible to avoid the danger from the reacting
force when motor speed changes.
STEP 1:
Set the value of parameter P1-01 to 4 and it is speed (Sz) control mode. Please ensure to set P1-01 when
the servo drive is Off (Servo Off). After selecting the operation mode as speed (Sz) control mode, please
restart the drive as P1-01 is effective only after the servo drive is restarted (after switching power off and on).
STEP 2:
In speed control mode, the necessary Digital Inputs are listed as follows:
Digital Input
Parameter Setting
Value
Sign
Function Description
CN1 PIN No.
DI1 P2-10=101
SON
Servo
On
DI1-=17
DI2
P2-11=109
TRQLM
Torque limit enabled
DI2-=18
DI3
P2-12=114
SPD0
Speed command selection 0
DI3-=5
DI4
P2-13=115
SPD1
Speed command selection 1
DI4-=3
DI5 P2-14=102
ARST
Alarm
Reset
DI5-=15
DI6
P2-15=0
Disabled
This DI function is disabled
DI6-=14
By default, DI4 is the function of reverse inhibit limit, DI5 is the function of forward inhibit limit and DI6 is the
function of emergency stop (DI6), if the users do not set the setting value of parameters P2-13 to P2-15 to 0
(Disabled), the faults (ALE13, 14 and 15) will occur (For the information of fault messages, please refer to
Chapter 10). Therefore, if the users do not need to use these three digit inputs, please set the setting value
of parameters P2-13 to P2-15 to 0 (Disabled) in advance. Now, we need to use DI4 and D5 (please refer to
the above table), so it only needs to disable the DI6, i.e. set the setting value of parameter P2-15 to 0.
All the digital inputs of Delta ASDA-B series are user-defined, and the user can set the DI signals freely.
Ensure to refer to the definitions of DI signals before defining them (For the description of DI signals, please
refer to Table 7.A in Chapter 7).
The speed command is selected by SPD0, SPD1. Please refer to the following table:
DI signal of CN1
Speed
Command No.
SPD1
SPD0
Command Source
Content
Range
S1 0
0 N/A
Speed command is
0(zero)
N/A
S2
0
1
P1-09
-5000 ~ 5000rpm
S3
1
0
P1-10
-5000 ~ 5000rpm
S4 1
1
Internal parameter
P1-11
-5000 ~ 5000rpm
0: indicates OFF (Normally Open); 1: indicates ON (Normally Closed)
If any alarm code displays after the setting is completed, the users can restart the drive or set DI5 to be
activated to clear the fault. Please refer to section 5.2.
Содержание ASD-B0121-A
Страница 1: ......
Страница 13: ...Table of Contents ASDA B Series Revision January 2009 This page intentionally left blank...
Страница 18: ...Chapter 1 Unpacking Check and Model Explanation ASDA B Series Revision January 2009 1 5 ECMA Series Servo Motor...
Страница 53: ...Chapter 3 Connections and Wiring ASDA B Series 3 28 Revision January 2009 3 6 2 Speed Control Mode...
Страница 54: ...Chapter 3 Connections and Wiring ASDA B Series Revision January 2009 3 29 3 6 3 Torque Control Mode...
Страница 55: ...Chapter 3 Connections and Wiring ASDA B Series 3 30 Revision January 2009 This page intentionally left blank...
Страница 72: ...Chapter 4 Display and Operation ASDA B Series Revision January 2009 4 17 Figure 4 7...
Страница 75: ...Chapter 4 Display and Operation ASDA B Series 4 20 Revision January 2009 Figure 4 9...
Страница 77: ...Chapter 4 Display and Operation ASDA B Series 4 22 Revision January 2009 Figure 4 10...
Страница 79: ...Chapter 4 Display and Operation ASDA B Series 4 24 Revision January 2009 Figure 4 11...
Страница 92: ...Chapter 4 Display and Operation ASDA B Series Revision January 2009 4 37 Figure 4 21...
Страница 93: ...Chapter 4 Display and Operation ASDA B Series 4 38 Revision January 2009 This page intentionally left blank...
Страница 115: ...Chapter 5 Trial Run and Tuning Procedure ASDA B Series 5 22 Revision January 2009 This page intentionally left blank...
Страница 255: ...Chapter 9 Maintenance and Inspection ASDA B Series 9 4 Revision January 2009 This page intentionally left blank...
Страница 277: ...Chapter 11 Specifications ASDA B Series 11 10 Revision January 2009 11 4 Servo Motor Speed Torque Curves T N Curve...
Страница 291: ...Chapter 12 Application Examples ASDA B Series 12 2 Revision January 2009 PLC Program...
Страница 292: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 3...
Страница 293: ...Chapter 12 Application Examples ASDA B Series 12 4 Revision January 2009...
Страница 296: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 7 HMI DOP A HMI Program Screen Homing Operation...
Страница 297: ...Chapter 12 Application Examples ASDA B Series 12 8 Revision January 2009 Position Control 1...
Страница 298: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 9 Position Control 2...
Страница 299: ...Chapter 12 Application Examples ASDA B Series 12 10 Revision January 2009 JOG Operation...
Страница 302: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 13...
Страница 305: ...Chapter 12 Application Examples ASDA B Series 12 16 Revision January 2009 Connecting to Delta DVP 01PU...
Страница 306: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 17 Connecting to Mitsubishi FX1PG...
Страница 307: ...Chapter 12 Application Examples ASDA B Series 12 18 Revision January 2009 Connecting to Mitsubishi FX2N1PG...
Страница 308: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 19 Connecting to Mitsubishi AD75...
Страница 309: ...Chapter 12 Application Examples ASDA B Series 12 20 Revision January 2009 This page intentionally left blank...