Chapter 10 Troubleshooting
|
ASDA-B Series
Revision January 2009
10-5
ALE 6 / ALE : Overload
When the motor is started within 30 minutes:
Potential Cause
Checking Method
Corrective Actions
The drive has exceeded
its rated load during
continuous operation.
Check if the drive is overloaded.
Increase motor capacity or reduce
load.
Check if there is mechanical vibration
Adjust gain value of control circuit.
Control system
parameter setting is
incorrect.
Accel/Decel time setting is too fast.
Decrease Accel/Decel time setting.
The wiring of drive and
encoder is in error.
Check the wiring of U, V, W and encoder.
Ensure all wiring is correct.
The encoder of the
motor is damaged.
Please contact your distributor for assistance or contact with Delta.
The connection of U, V,
W is incorrect.
Ensure the U, V, W of the motor is connected
to the U, V, W of the drive correctly.
Ensure all wiring is correct.
When the motor start running for 3 minutes above:
Potential Cause
Checking Method
Corrective Actions
The drive has exceeded
its rated load during
continuous operation.
Check if the drive is overloaded.
Increase motor capacity or reduce
load.
Check if there is mechanical vibration
Adjust gain value of control circuit.
Control system
parameter setting is
incorrect.
Accel/Decel time setting is too fast.
Decrease Accel/Decel time setting.
The wiring of drive and
encoder is in error.
Check the wiring of U, V, W and encoder.
Ensure all wiring is correct.
ALE 7 / ALE : Overspeed
When SERVO ON:
Potential Cause
Checking Method
Corrective Actions
The wiring of motor is
incorrect.
Check the wiring of U, V, W and encoder.
Ensure all wiring is correct.
The encoder of the
motor is damaged.
Please contact your distributor for assistance or contact with Delta.
When the motor Accel/Decel in high-speed:
Potential Cause
Checking Method
Corrective Actions
Speed input command
is not stable (too much
fluctuation).
Use signal detector to detect if input signal is
abnormal.
Ensure that input command
frequency is stable (not fluctuate
too much) and activate filter
function (P1-06, P1-07 and P1-08).
Over-speed parameter
setting is defective.
Check if over-speed parameter setting value is
too low.
Correctly set over-speed parameter
setting (P2-34).
Содержание ASD-B0121-A
Страница 1: ......
Страница 13: ...Table of Contents ASDA B Series Revision January 2009 This page intentionally left blank...
Страница 18: ...Chapter 1 Unpacking Check and Model Explanation ASDA B Series Revision January 2009 1 5 ECMA Series Servo Motor...
Страница 53: ...Chapter 3 Connections and Wiring ASDA B Series 3 28 Revision January 2009 3 6 2 Speed Control Mode...
Страница 54: ...Chapter 3 Connections and Wiring ASDA B Series Revision January 2009 3 29 3 6 3 Torque Control Mode...
Страница 55: ...Chapter 3 Connections and Wiring ASDA B Series 3 30 Revision January 2009 This page intentionally left blank...
Страница 72: ...Chapter 4 Display and Operation ASDA B Series Revision January 2009 4 17 Figure 4 7...
Страница 75: ...Chapter 4 Display and Operation ASDA B Series 4 20 Revision January 2009 Figure 4 9...
Страница 77: ...Chapter 4 Display and Operation ASDA B Series 4 22 Revision January 2009 Figure 4 10...
Страница 79: ...Chapter 4 Display and Operation ASDA B Series 4 24 Revision January 2009 Figure 4 11...
Страница 92: ...Chapter 4 Display and Operation ASDA B Series Revision January 2009 4 37 Figure 4 21...
Страница 93: ...Chapter 4 Display and Operation ASDA B Series 4 38 Revision January 2009 This page intentionally left blank...
Страница 115: ...Chapter 5 Trial Run and Tuning Procedure ASDA B Series 5 22 Revision January 2009 This page intentionally left blank...
Страница 255: ...Chapter 9 Maintenance and Inspection ASDA B Series 9 4 Revision January 2009 This page intentionally left blank...
Страница 277: ...Chapter 11 Specifications ASDA B Series 11 10 Revision January 2009 11 4 Servo Motor Speed Torque Curves T N Curve...
Страница 291: ...Chapter 12 Application Examples ASDA B Series 12 2 Revision January 2009 PLC Program...
Страница 292: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 3...
Страница 293: ...Chapter 12 Application Examples ASDA B Series 12 4 Revision January 2009...
Страница 296: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 7 HMI DOP A HMI Program Screen Homing Operation...
Страница 297: ...Chapter 12 Application Examples ASDA B Series 12 8 Revision January 2009 Position Control 1...
Страница 298: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 9 Position Control 2...
Страница 299: ...Chapter 12 Application Examples ASDA B Series 12 10 Revision January 2009 JOG Operation...
Страница 302: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 13...
Страница 305: ...Chapter 12 Application Examples ASDA B Series 12 16 Revision January 2009 Connecting to Delta DVP 01PU...
Страница 306: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 17 Connecting to Mitsubishi FX1PG...
Страница 307: ...Chapter 12 Application Examples ASDA B Series 12 18 Revision January 2009 Connecting to Mitsubishi FX2N1PG...
Страница 308: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 19 Connecting to Mitsubishi AD75...
Страница 309: ...Chapter 12 Application Examples ASDA B Series 12 20 Revision January 2009 This page intentionally left blank...