Appendix B: ASBX/40 Module
TMC 188/40 Motion Control Module
Delta Computer Systems, Inc. 360/254-8688
82
Pressure Plots
A TMC 188/40-TA automatically records pressure readings during a move. This data can be used by
DCSMON to generate screen plots or saved to disk for reference or diagnostic purposes.
Connector
The TMC 188/40-TA is supplied with a cable and 37-pin D-sub connector. The wiring is as follows:
PIN #
Function
Wire Color
1
Axis 1 + input
BLACK pair 1
20
Axis 1 - input
RED pair 1
Shell
Shield
2
Axis 2 + input
BLACK pair 2
21
Axis 2 - input
WHITE pair 2
Shell
Shield
3
Axis 3 + input
BLACK pair 3
22
Axis 3 - input
GREEN pair 3
Shell
Shield
4
Axis 4 + input
BLACK pair 4
23
Axis 4 - input
BLUE pair 4
Shell
Shield
5
Analog Common
BLACK pair 5
24
N.C.
YELLOW pair 5
6
N.C
BLACK pair 6
25
Digital Common
BROWN pair 6
7
B1
BLACK pair 7
26
B2
ORANGE pair 7
8
B3
RED pair 8
27
B4
WHITE pair 8
9-19
N.C.
28-37
N.C.