snmp authentication SNMP_AUTH_FAIL:SNMP Authentication failed.Request with
invalid community string.
snmp coldstart SNMP_COLD_START: Agent Initialized - SNMP COLD_START.
SNMP_WARM_START:Agent Initialized - SNMP WARM_START.
snmp linkdown PORT_LINKDN:changed interface state to down:%d
snmp linkup PORT_LINKUP:changed interface state to up:%d
Enabling a Subset of SNMP Traps
You can enable a subset of Dell Networking enterprise-specific SNMP traps using one of the following
listed command options.
To enable a subset of Dell Networking enterprise-specific SNMP traps, use the following command.
• Enable a subset of SNMP traps.
snmp-server enable traps
NOTE: The
envmon
option enables all environment traps including those traps that are enabled
with the
envmon supply
,
envmon temperature
, and
envmon fan
options.
Example of Dell Networking Enterprise-specific SNMP Traps
envmon
CARD_SHUTDOWN: %sLine card %d down - %s
CARD_DOWN: %sLine card %d down - %s
LINECARDUP: %sLine card %d is up
CARD_MISMATCH: Mismatch: line card %d is type %s - type %s required.
RPM_STATE: RPM1 is in Active State
RPM_STATE: RPM0 is in Standby State
RPM_DOWN: RPM 0 down - hard reset
RPM_DOWN: RPM 0 down - card removed
HOT_FAILOVER: RPM Failover Completed
SFM_DISCOVERY: Found SFM 1
SFM_REMOVE: Removed SFM 1
MAJOR_SFM: Major alarm: Switch fabric down
MAJOR_SFM_CLR: Major alarm cleared: Switch fabric up
MINOR_SFM: MInor alarm: No working standby SFM
MINOR_SFM_CLR: Minor alarm cleared: Working standby SFM present
TASK SUSPENDED: SUSPENDED - svce:%d - inst:%d - task:%s
RPM0-P:CP %CHMGR-2-CARD_PARITY_ERR
ABNORMAL_TASK_TERMINATION: CRASH - task:%s %s
CPU_THRESHOLD: Cpu %s usage above threshold. Cpu5SecUsage (%d)
CPU_THRESHOLD_CLR: Cpu %s usage drops below threshold. Cpu5SecUsage (%d)
MEM_THRESHOLD: Memory %s usage above threshold. MemUsage (%d)
MEM_THRESHOLD_CLR: Memory %s usage drops below threshold. MemUsage (%d)
DETECT_STN_MOVE: Station Move threshold exceeded for Mac %s in vlan %d
CAM-UTILIZATION: Enable SNMP envmon CAM utilization traps.
envmon supply
PEM_PRBLM: Major alarm: problem with power entry module %s
PEM_OK: Major alarm cleared: power entry module %s is good
MAJOR_PS: Major alarm: insufficient power %s
MAJOR_PS_CLR: major alarm cleared: sufficient power
MINOR_PS: Minor alarm: power supply non-redundant
MINOR_PS_CLR: Minor alarm cleared: power supply redundant
envmon temperature
MINOR_TEMP: Minor alarm: chassis temperature
MINOR_TEMP_CLR: Minor alarm cleared: chassis temperature normal (%s %d
temperature is within threshold of %dC)
Simple Network Management Protocol (SNMP)
933
Содержание S4820T
Страница 1: ...Dell Configuration Guide for the S4820T System 9 8 0 0 ...
Страница 282: ...Dell 282 Control Plane Policing CoPP ...
Страница 569: ...Figure 62 Inspecting Configuration of LAG 10 on ALPHA Link Aggregation Control Protocol LACP 569 ...
Страница 572: ...Figure 64 Inspecting a LAG Port on BRAVO Using the show interface Command 572 Link Aggregation Control Protocol LACP ...
Страница 573: ...Figure 65 Inspecting LAG 10 Using the show interfaces port channel Command Link Aggregation Control Protocol LACP 573 ...
Страница 617: ...mac address table static multicast mac address vlan vlan id output range interface Microsoft Network Load Balancing 617 ...
Страница 622: ...Figure 81 Configuring Interfaces for MSDP 622 Multicast Source Discovery Protocol MSDP ...
Страница 623: ...Figure 82 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 623 ...
Страница 624: ...Figure 83 Configuring PIM in Multiple Routing Domains 624 Multicast Source Discovery Protocol MSDP ...
Страница 629: ...Figure 86 MSDP Default Peer Scenario 2 Multicast Source Discovery Protocol MSDP 629 ...
Страница 630: ...Figure 87 MSDP Default Peer Scenario 3 630 Multicast Source Discovery Protocol MSDP ...
Страница 751: ...10 11 5 2 00 00 05 00 02 04 Member Ports Te 1 2 1 PIM Source Specific Mode PIM SSM 751 ...
Страница 905: ...Figure 112 Single and Double Tag First byte TPID Match Service Provider Bridging 905 ...
Страница 979: ...6 Member not present 7 Member not present Stacking 979 ...
Страница 981: ...storm control Storm Control 981 ...
Страница 999: ... Te 1 1 0 INCON Root Rootguard Te 1 2 0 LIS Loopguard Te 1 3 0 EDS Shut Bpduguard Spanning Tree Protocol STP 999 ...
Страница 1103: ...Figure 134 Setup OSPF and Static Routes Virtual Routing and Forwarding VRF 1103 ...