About Your System
39
Embedded NIC
x
and
NIC
y
:
OS NIC=
<ENABLED
|DISABLED>
,
Management
Shared NIC=
<ENABLED
|DISABLED>
The OS NIC interface is set
in BIOS. The Management
Shared NIC interface is set in
management tools.
Check the system
management software or
the System Setup program
for NIC settings. If a
problem is indicated,
see "Troubleshooting a NIC"
on page 131.
Error 8602 -
Auxiliary Device
Failure. Verify
that mouse and
keyboard are
securely
attached to
correct
connectors.
Mouse or keyboard cable
is loose or improperly
connected.
Reseat the mouse or
keyboard cable.
Defective mouse or keyboard. Ensure that the mouse
or keyboard is operational.
See "Troubleshooting a USB
Device" on page 130.
Gate A20 failure
Faulty keyboard controller;
faulty system board.
See "Getting Help" on
page 157.
Table 1-2. System Messages
(continued)
Message
Causes
Corrective Actions