About Your System
37
Alert! Power
required exceeds
PSU wattage.
Check PSU and
system
configuration.
Alert!
Continuing
system boot
accepts the risk
that system may
power down
without warning.
The system configuration of
processor, memory modules,
and expansion cards may
not be supported by the
power supply.
If any system components
were just upgraded, return
the system to the previous
configuration. If the system
boots without this warning,
then the replaced
component(s) are not
supported with this power
supply. See "Chassis
Intrusion Switch" on
page 118.
Alert! System
fatal error
during previous
boot.
An error caused the
system to reboot.
Check other system
messages for
additional information
for possible causes.
BIOS
MANUFACTURING
MODE detected.
MANUFACTURING
MODE will be
cleared before
the next boot.
System reboot
required for
normal
operation.
System is in
manufacturing mode.
Reboot to take the system
out of manufacturing mode.
BIOS Update
Attempt Failed!
Remote BIOS update
attempt failed.
Retry the BIOS update.
If the problem persists,
see "Getting Help" on
page 157.
Table 1-2. System Messages
(continued)
Message
Causes
Corrective Actions
book.book Page 37 Monday, August 9, 2010 3:07 PM
Содержание PowerVault NX200
Страница 1: ...Dell PowerVault NX200 Systems Hardware Owner s Manual ...
Страница 10: ...10 Contents ...
Страница 74: ...72 Using the System Setup Program and UEFI Boot Manager ...
Страница 130: ...128 Installing System Components ...
Страница 148: ...146 Troubleshooting Your System ...
Страница 160: ...158 Getting Help ...
Страница 166: ...164 Index ...