Figure 44. Removing and installing the PSU blank
1.
PSU blank
2. PSU bay
Next steps
Install the PSU or PSU blank.
Related Tasks
Installing the power supply unit blank
Installing a redundant AC power supply unit
Installing the power supply unit blank
Install the power supply unit (PSU) blank only in the second PSU bay.
Prerequisites
CAUTION: To ensure proper system cooling, the PSU blank must be installed in the second PSU
bay in a non-redundant configuration. Remove the PSU blank only if you are installing a second
PSU.
Steps
Align the PSU blank with the PSU bay, and push the PSU blank into the chassis until it clicks into
place.
Replacing the power supply unit divider
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
1.
Turn off the system, including any attached peripherals, and disconnect the system from the
electrical outlet and peripherals.
2.
If installed, remove the redundant power supply units (PSUs) or PSU blank.