About Your System
27
E1620 PS # Input
Range
Power source for specified
power supply is
unavailable, or out of
acceptable range.
Check the AC power
source for the specified
power supply. If problem
persists, see
"Troubleshooting Power
Supplies" on page 137.
E1624 PS
Redundancy
The power supply
subsystem is no longer
redundant. If the last
supply fails, the system will
go down.
See "Troubleshooting
Power Supplies" on
page 137.
E1710 I/O Channel
Chk
The system BIOS has
reported an I/O channel
check.
See "Getting Help" on
page 165.
E1711 PCI PERR
B## D## F##
PCI PERR
Slot #
The system BIOS has
reported a PCI parity error
on a component that
resides in PCI
configuration space at bus
##, device ##, function
##.
The system BIOS has
reported a PCI parity error
on a component that
resides in the specified PCI
slot.
Remove and reseat the PCI
expansion cards. If the
problem persists, see
"Troubleshooting
Expansion Cards" on
page 145.
If the problem persists, the
riser card or system board
is faulty. See "Getting
Help" on page 165.
PCI PERR
Slot #
The system BIOS has
reported a PCI parity error
on a component that
resides in the specified PCI
slot.
Remove and reseat the PCI
expansion cards. If the
problem persists, see
"Troubleshooting
Expansion Cards" on
page 145.
If the problem persists, the
riser card or system board
is faulty. See "Getting
Help" on page 165.
Table 1-5. LCD Status Messages
Code
Test
Causes
Corrective Actions
Содержание PowerEdge R900
Страница 1: ...Dell PowerEdge R900 Systems Hardware Owner s Manual ...
Страница 10: ...10 Contents Glossary 171 ...
Страница 40: ...40 About Your System ...
Страница 56: ...56 Using the System Setup Program ...
Страница 81: ...Installing System Components 81 Figure 3 11 2 5 Inch SAS SAS RAID Cabling 10 7 6 5 8 9 2 1 4 3 ...
Страница 83: ...Installing System Components 83 Figure 3 12 3 5 Inch SAS SAS RAID Cabling 8 4 2 5 6 3 7 1 9 10 ...
Страница 126: ...126 Installing System Components ...
Страница 164: ...164 Jumpers and Connectors ...
Страница 190: ...190 Index ...