About Your System
17
Table 1-2. Hard Drive Indicators
Pattern
Green element
Amber eLement
Drive/slot state
Slot empty
Off
Off
The slot is empty, an
unsupported drive is
present, the drive has
been spun down for
removal (Ready for
Removal), or a new
drive has been inserted,
and the state has not
been updated by the
RAID controller.
Drive online
On
Off
The drive is either
online, ready, a hotspare
or a foreign drive.
Drive identify
(prep for removal)
On ~250mS
Off ~250mS
Off
The slot is being
identified because of a
user request (either a
drive identify or a
preparing for removal
was requested).
Drive rebuilding
On ~400mS
Off ~100mS
Off
The drive is being
written to, to make a
virtual disk redundant.
Drive failed
Off
On ~150mS
Off ~150mS
The RAID controller
can no longer access or
control (read/write to)
the drive because it has
detected an
unrecoverable fault
(after it has completed
its error handling) on
the drive.
Predicted Failure
(SMART)
On ~500mS
Off ~500mS
Off ~1000S
Off ~500mS
On ~500mS
Predictive failure event
has been reported by
the drive.
Содержание PowerEdge R900
Страница 1: ...Dell PowerEdge R900 Systems Hardware Owner s Manual ...
Страница 10: ...10 Contents Glossary 171 ...
Страница 40: ...40 About Your System ...
Страница 56: ...56 Using the System Setup Program ...
Страница 81: ...Installing System Components 81 Figure 3 11 2 5 Inch SAS SAS RAID Cabling 10 7 6 5 8 9 2 1 4 3 ...
Страница 83: ...Installing System Components 83 Figure 3 12 3 5 Inch SAS SAS RAID Cabling 8 4 2 5 6 3 7 1 9 10 ...
Страница 126: ...126 Installing System Components ...
Страница 164: ...164 Jumpers and Connectors ...
Страница 190: ...190 Index ...