26
About Your System
E141F CPU
Protocol
The system BIOS has
reported a processor
protocol error.
See "Getting Help" on
page 165.
E1420 CPU Bus
PERR
The system BIOS has
reported a processor
protocol error.
See "Getting Help" on
page 165.
E1421 CPU Init
The system BIOS has
reported a processor
initialization error.
See "Getting Help" on
page 165.
E1422 CPU Machine
Chk
The system BIOS has
reported a machine check
error.
See "Getting Help" on
page 165.
E1610 PS #
Missing
No power is available from
the specified power supply;
specified power supply is
improperly installed or
faulty.
See "Troubleshooting
Power Supplies" on
page 137.
E1614 PS # Status
No power is available from
the specified power supply;
specified power supply is
improperly installed or
faulty.
See "Troubleshooting
Power Supplies" on
page 137.
E1618 PS #
Predictive
Power supply voltage is out
of acceptable range;
specified power supply is
improperly installed or
faulty.
See "Troubleshooting
Power Supplies" on
page 137.
E161C PS # Input
Lost
Power source for specified
power supply is
unavailable, or out of
acceptable range.
Check the AC power
source for the specified
power supply. If problem
persists, see
"Troubleshooting Power
Supplies" on page 137.
Table 1-5. LCD Status Messages
Code
Test
Causes
Corrective Actions
Содержание PowerEdge R900
Страница 1: ...Dell PowerEdge R900 Systems Hardware Owner s Manual ...
Страница 10: ...10 Contents Glossary 171 ...
Страница 40: ...40 About Your System ...
Страница 56: ...56 Using the System Setup Program ...
Страница 81: ...Installing System Components 81 Figure 3 11 2 5 Inch SAS SAS RAID Cabling 10 7 6 5 8 9 2 1 4 3 ...
Страница 83: ...Installing System Components 83 Figure 3 12 3 5 Inch SAS SAS RAID Cabling 8 4 2 5 6 3 7 1 9 10 ...
Страница 126: ...126 Installing System Components ...
Страница 164: ...164 Jumpers and Connectors ...
Страница 190: ...190 Index ...