Identify a faulted I/O module from PowerStore Manager
Before you replace an I/O module, ensure that you have identified its location within the system. Using PowerStore Manager,
you can identify and locate a faulted I/O module.
Steps
1. From PowerStore Manager, select
Hardware
.
2. Select the appliance that includes the I/O module that you need to replace.
3. On the
Components
card, under
Rear View
, expand
BaseEnclosure
.
4. Expand the node that includes the I/O module, and then select the relevant
IoModule
.
Faulted parts appear in red in the image of the system, and report a status of
Faulted
in the
State
field.
Base enclosure I/O module LEDs
Use the fault LEDs to identify the faulted part.
NOTE:
The ports look different depending on whether they are for copper or optical connections. The image below shows
ports for copper cables.
Figure 50. Base enclosure I/O module LEDs
Table 4. Base enclosure I/O module LEDs
LED
Location
State
Description
Port link
Green or blue
Link up
Off
Link down
Power fault
Green
Power on
Amber
Power fault
Power down the node
Power down the node as described in
.
Remove a faulted I/O module
Steps
1. Pull the trigger mechanism on the I/O module handle to release it.
Base enclosure service procedures
51