Figure 22. Installing a 2.5" drive
5. If you are installing an NVMe NVRAM drive, push the latch cover into place.
The activity light flashes to indicate that the spin-up sequence has begun.
Verify the operation of a replacement drive
Steps
1. From PowerStore Manager, select
Hardware
.
2. Select the appliance where you replaced the drive.
3. On the
Components
card, under
Drives
, expand
BaseEnclosure
and select the drive.
The status of the replacement drive should read
Healthy
. If the status is still
Faulted
, wait a few minutes and refresh
PowerStore Manager. If the status does not change, ensure that the drive is correctly seated, or contact your service
provider.
4. Click
Stop Blink LED
.
Return a faulted part
About this task
For US customers, return defective material within five business days. For International customers, return defective material
within 10 business days. The materials required to return your defective part are supplied with the good part shipment.
Base enclosure service procedures