Item Indicator, Button, or Connector
Description
11
Server modules
Up to four PowerEdge M520, M620, M630, or M640 server modules or 2 M820
server modules configured for the enclosure.
Minimum CMC Version
The following table lists the minimum CMC version required to enable the listed server modules.
Table 4. Minimum CMC Version for server modules
Servers
Minimum version of CMC
PowerEdge M520
CMC 1.36
PowerEdge M620
CMC 1.36
PowerEdge M820
CMC 1.36
PowerEdge M630
CMC 2.00
PowerEdge M830
CMC 2.00
PowerEdge M640
CMC 3.00
The following table lists the minimum CMC version required to enable the listed I/O moduless.
Table 5. Minimum CMC Version for I/O modules
IOM Switches
Minimum version of CMC
R1 VRTX 1Gb Pass-through
CMC 1.20
R1-2401 VRTX 1GbE Switch
CMC 1.20
R1-2210 VRTX 10Gb Switch
CMC 2.00
Supported Remote Access Connections
The following table lists the supported Remote Access Controllers.
Table 6. Supported Remote Access Connections
Connection
Features
CMC Network Interface ports
•
GB port: Dedicated network interface for the CMC web interface.
•
DHCP support.
•
SNMP traps and e-mail event notification.
•
Network interface for the iDRAC and I/O Modules (IOMs).
•
Support for Telnet/SSH command console and RACADM CLI commands including
system boot, reset, power-on, and shutdown commands.
Serial port
•
Support for serial console and RACADM CLI commands including system boot, reset,
power-on, and shutdown commands.
•
Support for binary interchange for applications designed to communicate with a binary
protocol to a particular type of I/O Module.
•
Serial port can be connected internally to the serial console of a server, or I/O module,
using the connect (or racadm connect) command.
•
Provides access only to the active CMC.
Supported Platforms
CMC supports modular servers designed for the PowerEdge VRTX platform. For information about compatibility with CMC, see the
documentation for your device.