A6
Magazine Missing
Verify the magazine or magazine blank is fully inserted into the autoloader.
Remove and re-insert the magazine.
Try a second magazine if possible.
Power cycle the autoloader.
If the error continues, contact
A7
Mail Slot Full
Remove any previously ejected media from the mail slot.
Verify that there is no debris or foreign object in the mail slot opening.
Verify the mail slot door is fully closed.
If the error continues, contact
A8
Destination Element Full
Verify that the expected destination element already has a cartridge.
Power cycle the autoloader.
Run the Random Moves test from either the Remote Management Unit
(RMU) or the Operator Control Panel (OCP).
Note: The Random Moves test requires a minimum of two cartridges
present within the autoloader.
If the destination is a slot within a magazine, check if the spring loaded
cartridge present flag moves freely when the cartridge is manually inserted
into the magazine
If the error continues, contact
A9
Picker Full
Look in the front of the autoloader and confirm the picker is full.
Execute a Move command from the Operator Control Panel to move the
cartridge from the picker to a location.
Power cycle the autoloader through the front panel.
Run the Random Moves test from either the Remote Management Unit
(RMU) or the Operator Control Panel (OCP).
Note: The Random Moves test requires a minimum of two cartridges
present within the autoloader.
If the source is a slot within a magazine, check if the spring loaded
cartridge present flag moves freely when the cartridge is manually inserted
into the magazine.
If all previous steps fail, contact
AA
Picker Cartridge Sensor
Error
AB
Drive Path Sensor Error
Power cycle the autoloader through the front panel.
Run the Random Moves test from either the Remote Management Unit
(RMU) or the Operator Control Panel (OCP).
Note: The Random Moves test requires a minimum of two cartridges
present within the autoloader.
If all previous steps fail, contact
AC
Mail Slot Door Sensor Error
Power cycle the autoloader.