SCSI ID
A digit 0 through 7 (default 6). The assigned SCSI ID for the autoloader.
Magazines
L=*
Asterisk indicates the left magazine is present.
R=*
Asterisk indicates the right magazine is present.
BC Reader
Yes
Bar code reader enabled
No
Bar code reader disabled
Viewing Firmware Version
To view the current firmware version, use the following procedure:
1. From the main menu, scroll to
Status
, and then press
Enter
.
2. From the
Status
submenu, scroll to
Autoloader
, and then press
Enter
.
3. From the
Autoloader
submenu, scroll to
Version
, and then press
Enter
.
A list of messages appears on the LCD. The firmware version is listed as
Firmware: VX.XX
where
X.XX
is the current
installed version of the firmware.
Firmware
The number indicates the firmware version.
EDC
The number indicates the Error Correction Code that was generated when the firmware was installed.
The autoloader uses this number to verify that the firmware and the memory holding the firmware are
good.
HW Rev
The number indicates the hardware version.
ME Rev
The number indicates the mechanical version.
Viewing Element Status
The element status reports the status of the magazine slots. The status indicates whether a slot contains a cartridge or not,
and which slot is allocated as the cleaning cartridge's slot. To view an element's status:
1. From the main menu, scroll to
Status
, and then press
Enter
.
2. From the
Status
submenu, scroll to
Autoloader
, and then press