Message Error Types
26
Message Sender (Task ) ID
Error
Verify the host backup application and device driver are at the latest
Check host adapter and SCSI cables and terminator.
Power cycle the autoloader and retry the operation.
If all previous steps fail, contact
27
Message Type Bad
28
Message Parameter Bad
Stack/Global Data Corruption Error Types
29
Invalid Element
Verify the host backup application and device driver are at the latest
Power cycle the autoloader.
Run the Random Moves test from either the Remote Management Unit
(RMU) or the Operator Control Panel (OCP).
Note: The Random Moves test requires a minimum of two cartridges
present within the autoloader.
If all previous steps fail, contact
2A
Invalid Element Status
2B
Element Table Bad
2C
Global Data Bad
2D
Stack Data Bad
2E
Task Stack Low
2F
Task Stack Overflow
System Shutdown/Disruption Error Types
30
POST Failure
Verify that the magazines/magazine blank are fully seated.
Power cycle the autoloader.
If all previous steps fail, contact
31
Watchdog Timer
Power cycle the autoloader.
Run the Random Moves test from either the Remote Management Unit
(RMU) or the Operator Control Panel (OCP).
Note: The Random Moves test requires a minimum of two cartridges
present within the autoloader.
for PowerVault 124T firmware updates.
If all previous steps fail, contact
32
Power Event
33
Power Down Failure
34
System Overload
35
System Performance
36
Asynchronous Stop
System Miscellaneous Error Types
37
System Cleaning Error
Cleaning slot in use.
Verify that a valid cleaning cartridge is located in the dedicated cleaning
slot indicated within the Remote Management Unit Configuration page
settings.
for PowerVault 124T firmware updates.
If all previous steps fail, contact
38
System Internal I2C HW
Error
Contact