background image

Problem

Cause

Solution(s)

A)  The  Salt  Chlorinator 

plates  have  scale 

build-up.

A) Look through the salt chlorinator cell, checking for 

any white scale build-up on the plates. If scale build-

up  is  found,  clean  the  chlorinator  cell  plates  per  

Section 5d-1. Add Del-Quest as needed. Check and 

balance pool chemistry as required after cleaning.

B)  The  Salt  Chlorinator 

plates are shorting out 

due to a foreign object 

lodged in the cell.

B) Look through the salt chlorinator cell, checking for 

any object that may have gone through the filter and 

become stuck in the salt chlorinator plates  (i.e., hair-

pin, paper clip, etc.). Contact our telephone support 

number, 800.676.1335 ext. 293, for service.

C)  Cell  terminals  have 

become loose, discon-

nected, or corroded. 

D)  Voltage  ramping  too 

fast  (chlorine  control 

on max.

Problem

Causev

Solution(s)

\

Problem

Cause

Solution(s)

A) The TrioPure

TM

 is 

switched off.

A) Open the TrioPure

TM

 and turn the power switch on.

B) The TrioPure

TM

 is not 

getting power.

B) Check main pool circuit breaker. 

C) Internal tempera-

ture limit has been 

exceeded.

C) Allow the unit to cool down and re-start  

automatically

D) Main fuse is blown.

D) Check main fuse and replace if necessary. Note: A blown 

fuse can be caused by excessive salt levels above 5,000 

ppm with the 

Chlorine Control

 knob set to full power 

(10). Install 1 1/2 A for 240v & 3A for 120V input voltage. 

Call service if the main fuse blows repeatedly

TrioPure

TM

 

Sanitation System

19

Figure 27 

Figure 28

Figure 29 

DEL Ozone · San Luis Obispo, CA 93401 · USA · 800-676-1335 · Fax: 805-541-8459

A) Pool water low salin-

ity, low temperature, 

or calcium build-up  

on the chlorinator  

cell are restricting  

the amount of  

current drawn at the 

chlorinator cell.

B) Poor connection at 

chlorinator cell  

terminal post.

A) Check the pool salt level (salinity) and water tempera-

ture.  If either level is low this may affect the amount 

of chlorine production. If the tested free chlorine level 

is too low or if the pool shows signs of insufficient 

chlorine production (algae cloudy water condition) in 

the pool water you may increase the salinity slightly in 

order to make the TrioPure

TM

 

produce more chlorine. 

Add  salt  in  small  (25-50  pound)  increments  and 

allow 24 hours for the salt to dissolve before taking 

the next reading and making any more adjustments. 

Always keep the salinity below 5,000 ppm. If there 

is scale build-up, clean chlorinator cell per Section 

5d-1 and add Del-Quest as needed.

B) Clean and/or tighten connectors.

SECTION 6

 

Troubleshooting 

continued

C) Tighten, reconnect and/or clean as necessary.

D) Switch power off and turn down the 

Chlorine Control

 

knob. Switch power back on and wait 2 min. for unit 

to come out of clean mode (“CL”). Turn the Chlorine 

Control back up until the display just turns to 

10

.

Y

OL

Chlorine Production display reads OL

Chlorine Production display will not 

read all the way to 10

Indicator lights on front panel are not on.

Содержание TrioPure-25

Страница 1: ...San Luis Obispo CA 93401 USA 800 676 1335 Fax 805 541 8459 110105 4 0777 Rev J Installation and Operation Manual TrioPure 25 TrioPure 50 TrioPure Soft Water Ozone Sanitation System...

Страница 2: ...rioPure must be installed in an outdoor location or indoors in a well ventilated room and installed so that it is level and the orientation is as shown in Figures 1 2 This product manufactures chlorin...

Страница 3: ...3C Where to Get Salt 7 3D How Much Salt to Use 7 3E How to Add Salt 7 3F Pool Sizing Chart 7 3G Salt Sizing Table 8 3H When to Add Salt and Stabilizer 9 SECTION 4 Operation 4A Initial Start Up Procedu...

Страница 4: ...Ozone is made by drawing air through Corona Discharge CD cells that break down oxygen molecules which then recombine into ozone molecules The TrioPure s internal pump pro vides sufficient water flow t...

Страница 5: ...umb so that water from the TrioPure can go into the solar heater Also air bubbles from the solar return must not be allowed into the TrioPure inlet line Either install the bypass mani fold upstream of...

Страница 6: ...ion System DEL Ozone San Luis Obispo CA 93401 USA 800 676 1335 Fax 805 541 8459 2E Plumbing 2e 1 Installing the TrioPureTM Bypass Manifold Do not install the Bypass Manifold with the 2 section in a ve...

Страница 7: ...and non solar heaters Return from TrioPureTM plumbed to a dedicated 1 return to the lowest point of the pool where possible To minimize the size of ozone bubbles use a dispersion cap or main drain cov...

Страница 8: ...tallations where the bypass manifold causes too much flow restriction in the line The spa will be fed sanitized water through the spillway when the system is in pool mode When the system goes into spa...

Страница 9: ...tential fire and or electrical hazard Step 3 Open the front clear cover by removing the screw and opening the latch on the right side of the enclosure Step 4 Remove the front display plate by pulling...

Страница 10: ...alt Capture water from about 18 deep in a container and then test this water sample Add enough salt to obtain a salin ity of approximately 3 500 ppm Refer to Salt Sizing Table Figure 7 on pages 8 9 3E...

Страница 11: ...0 0 0 0 0 0 0 Over 5000 Dilute Dilute Dilute Dilute Dilute Dilute Dilute Dilute Dilute 25 500 26 000 26 500 27 000 27 500 28 000 28 500 29 000 29 500 0 745 759 774 789 803 818 833 847 862 250 692 705...

Страница 12: ...much salt you will need If existing stabilizer levels require it you may also need to add about 1 25 pounds of stabilizer Cyanuric Acid for every 50 pounds of salt added to the pool For example if ad...

Страница 13: ...nd not lit The Low Salt indicator blinks red when the pool should be checked for low salinity Warning always check salinity level with a test strip or digital meter before adding salt 4 High Salt Indi...

Страница 14: ...oPure power switch to ON The model either 25 or 50 will be displayed followed by the firmware revision number Then the display will show the current Chlorine Control setting S B OF Step 7 Observe the...

Страница 15: ...e flow ball on the flow meter does not move to the proper position go to Trouble Shooting Section 6A for assistance Step 9 Turn Chlorine Control knob up about half way pointing straight up Step 10 Obs...

Страница 16: ...ounts of either nitrates or phosphates can have a significant negative impact on the performance of ozone and chlorine in swimming pools If you experience conditions such as cloudy water or algae grow...

Страница 17: ...e submerged Allow the plates to soak for about 30 minutes or until effervescence stops and plates are clean Take care not to let the acid solution into the front chamber of the chlorinator cell as dam...

Страница 18: ...A 800 676 1335 Fax 805 541 8459 2 Disconnect quick disconnect fitting 4 Remove attachment shaft 5 Remove chlorinator cell by turning knob counterclockwise 1 Turn power off 6 Disconnect the two small e...

Страница 19: ...ke on the right side of the enclosure Figure 18 and the air exhaust at the bottom of the enclosure Figure 18 The screen filters are intended to keep insects and debris out of the TrioPureTM unit Allow...

Страница 20: ...00 ppm add salt run the pool pump for 24 hours then check the salt level again Repeat as needed to bring the salt level to within 3 000 to 5 000 PPM B Low Water Temp B Check the pool temperature If th...

Страница 21: ...red until the water temperature is above 59 F C Temperature sensor has become disconnected C Verify connections are correct and secure Problem Cause Solution s A The salt chlorinator is in Cleaning mo...

Страница 22: ...ll service if the main fuse blows repeatedly TrioPureTM Sanitation System 19 Figure 27 Figure 28 Figure 29 DEL Ozone San Luis Obispo CA 93401 USA 800 676 1335 Fax 805 541 8459 A Pool water low salin i...

Страница 23: ...n DEL will arrange for an Authorized Service Center to schedule a service call If a service provider isn t available within a reasonable distance as determined by DEL Ozone the product must be sent to...

Страница 24: ...ALANCE OF THE ORIGINAL WARRANTY PERIOD NOTE USE ONLY DEL OZONE AUTHORIZED REPLACEMENT PARTS USE OF ANY OTHER PART S WILL AUTOMATICALLY VOID THIS WARRANTY THIS LIMITED WARRANTY DOES NOT INCLUDE ANY OF...

Страница 25: ...email Date of Purchase Installed by Name of Company Date of installation Address Phone Number Type of Pool Above ground In ground Fiberglass Vinyl Gunite New Construction Remodeled Pool Retrofit to ex...

Страница 26: ......

Отзывы: