Problem
Cause
Solution(s)
A) The Salt Chlorinator
plates have scale
build-up.
A) Look through the salt chlorinator cell, checking for
any white scale build-up on the plates. If scale build-
up is found, clean the chlorinator cell plates per
Section 5d-1. Add Del-Quest as needed. Check and
balance pool chemistry as required after cleaning.
B) The Salt Chlorinator
plates are shorting out
due to a foreign object
lodged in the cell.
B) Look through the salt chlorinator cell, checking for
any object that may have gone through the filter and
become stuck in the salt chlorinator plates (i.e., hair-
pin, paper clip, etc.). Contact our telephone support
number, 800.676.1335 ext. 293, for service.
C) Cell terminals have
become loose, discon-
nected, or corroded.
D) Voltage ramping too
fast (chlorine control
on max.
Problem
Causev
Solution(s)
\
Problem
Cause
Solution(s)
A) The TrioPure
TM
is
switched off.
A) Open the TrioPure
TM
and turn the power switch on.
B) The TrioPure
TM
is not
getting power.
B) Check main pool circuit breaker.
C) Internal tempera-
ture limit has been
exceeded.
C) Allow the unit to cool down and re-start
automatically
D) Main fuse is blown.
D) Check main fuse and replace if necessary. Note: A blown
fuse can be caused by excessive salt levels above 5,000
ppm with the
Chlorine Control
knob set to full power
(10). Install 1 1/2 A for 240v & 3A for 120V input voltage.
Call service if the main fuse blows repeatedly
TrioPure
TM
Sanitation System
19
Figure 27
Figure 28
Figure 29
DEL Ozone · San Luis Obispo, CA 93401 · USA · 800-676-1335 · Fax: 805-541-8459
A) Pool water low salin-
ity, low temperature,
or calcium build-up
on the chlorinator
cell are restricting
the amount of
current drawn at the
chlorinator cell.
B) Poor connection at
chlorinator cell
terminal post.
A) Check the pool salt level (salinity) and water tempera-
ture. If either level is low this may affect the amount
of chlorine production. If the tested free chlorine level
is too low or if the pool shows signs of insufficient
chlorine production (algae cloudy water condition) in
the pool water you may increase the salinity slightly in
order to make the TrioPure
TM
produce more chlorine.
Add salt in small (25-50 pound) increments and
allow 24 hours for the salt to dissolve before taking
the next reading and making any more adjustments.
Always keep the salinity below 5,000 ppm. If there
is scale build-up, clean chlorinator cell per Section
5d-1 and add Del-Quest as needed.
B) Clean and/or tighten connectors.
SECTION 6
Troubleshooting
continued
C) Tighten, reconnect and/or clean as necessary.
D) Switch power off and turn down the
Chlorine Control
knob. Switch power back on and wait 2 min. for unit
to come out of clean mode (“CL”). Turn the Chlorine
Control back up until the display just turns to
10
.
Y
OL
Chlorine Production display reads OL
Chlorine Production display will not
read all the way to 10
Indicator lights on front panel are not on.