Problem
Cause
Solution(s)
A) The TrioPure
TM
has
detected a possible
high salt condition.
A) Check the salt level (salinity) of the pool water with
a test strip or digital meter. Never dilute the pool water
without verifying the salt level with a digital meter or test
strip first. If the salt level is over 5,000 ppm add fresh
water, run the pool pump for 24 hours, then check the
salt level again. Repeat as needed to reduce the salt
level to within 3,000 to 5,000 ppm.
Note:
Water must
be pumped out of the pool before fresh water can be
added to dilute the pool.
B) There is excessive
scale build-up or debris
on the chlorinator cell
plates.
B) If the tested salt level is within specified limits, check
the chlorinator cell plates for scale formation or debris
caught between the plates. Clean as required (refer
to Section 5d-1) Add Del-Quest as needed.
Note:
High
Salt Indicator may flash momentarily when adjusting
the Chlorine Control.
Problem
Cause
Solution(s)
A) The TrioPure
TM
has
detected a possible low
salt condition.
A) Check the salt level (salinity) of the pool water with
a test strip or digital meter. Never add salt to the pool
without verifying the salt level. If the salt level is below
3,000 ppm add salt, run the pool pump for 24 hours,
then check the salt level again. Repeat as needed to
bring the salt level to within 3,000 to 5,000 PPM.
B) Low Water Temp.
B) Check the pool temperature. If the pool water tem-
perature is low, combinations of low temperature and/
or
Chlorine Control
setting can cause the Low Salt LED
indicator to flash.
C) Low Power Setting
C) If
Chlorine Control
knob setting is set at the lower
end of the scale (from
1
to
4
), then disregard the
Low
Salt
indicator. Combinations of low temperature and/
or
Chlorine Control
setting can cause the
Low Salt
LED
indicator to flash.
Problem
Cause
Solution(s)
A) The ozone CD cell
has a blown fuse or
fuse clip is loose.
A) Trun unit off, open the enclosure, remove the front
panel and examine fuse on ozone board. Replace as
necessary, then pinch the fuse clips so the fuse snaps
into place then close up the TrioPure™ and restore
power.
B) There is a faulty
ozone power supply.
B) If replacement fuse blows (indicator goes red) on
power up, replace the ozone cell. Call for service. The
TrioPure™ will continue to work with the remaining
ozone CD cells.
17
Figure 21
Figure 22
Figure 23
DEL Ozone · San Luis Obispo, CA 93401 · USA · 800-676-1335 · Fax: 805-541-8459
SECTION 6
Troubleshooting
High-Salt Indicator LED is flashing
Low-Salt Indicator LED is flashing
Ozone Production Cell Indicators Turn Red
(O3 Cell 1–O3 Cell 4 for TrioPure™-50 & O3
Cell 1–O3 Cell 2 for TrioPure™-25)