background image

TrioPure

TM

 

Sanitation System

Problem

Cause

Solution(s)

A) The TrioPure

TM

 has 

detected a possible 

high salt condition.

A)  Check the salt level (salinity) of the pool water with 

a test strip or digital meter.  Never dilute the pool water 

without verifying the salt level with a digital meter or test 

strip first.  If the salt level is over 5,000 ppm add fresh 

water, run the pool pump for 24 hours, then check the 

salt level again.  Repeat as needed to reduce the salt 

level to within 3,000 to 5,000 ppm. 

Note: 

Water must 

be pumped out of the pool before fresh water can be 

added to dilute the pool.  

B) There is excessive 

scale build-up or debris 

on the chlorinator cell 

plates.

B) If the tested salt level is within specified limits, check 

the chlorinator cell plates for scale formation or debris 

caught  between  the  plates.  Clean  as  required  (refer 

to Section 5d-1) Add Del-Quest as needed. 

Note: 

High 

Salt Indicator may flash momentarily when adjusting 

the Chlorine Control.

Problem

Cause

Solution(s)

A) The TrioPure

TM

 has 

detected a possible low 

salt condition.

A) Check the salt level (salinity) of the pool water with 

a test strip or digital meter. Never add salt to the pool 

without verifying the salt level. If the salt level is below 

3,000 ppm add salt, run the pool pump for 24 hours, 

then check the salt level again. Repeat as needed to 

bring the salt level to within 3,000 to 5,000 PPM. 

B) Low Water Temp.

B) Check the pool temperature.  If the pool water tem-

perature is low, combinations of low temperature and/

or 

Chlorine Control

 setting can cause the Low Salt LED 

indicator to flash.

C) Low Power Setting

C) If 

Chlorine Control

 knob setting is set at the lower 

end of the scale (from 

1

 to 

4

), then disregard the 

Low 

Salt

 indicator. Combinations of low temperature and/

or 

Chlorine Control

 setting can cause the 

Low Salt

 LED 

indicator to flash.

Problem

Cause

Solution(s)

A) The ozone CD cell 

has a blown fuse or 

fuse clip is loose.

A) Trun unit off, open the enclosure, remove the front 

panel and examine fuse on ozone board. Replace as 

necessary, then pinch the fuse clips so the fuse snaps 

into  place  then  close  up  the  TrioPure™  and  restore 

power. 

B) There is a faulty 

ozone power supply.

B) If replacement fuse blows (indicator goes red) on 

power up, replace the ozone cell.  Call for service. The 

TrioPure™  will  continue  to  work  with  the  remaining 

ozone CD cells.

17

Figure 21 

Figure 22 

Figure 23 

DEL Ozone · San Luis Obispo, CA 93401 · USA · 800-676-1335 · Fax: 805-541-8459

SECTION 6

 

Troubleshooting

High-Salt Indicator LED is flashing

Low-Salt Indicator LED is flashing

Ozone Production Cell Indicators Turn Red 

(O3 Cell 1–O3 Cell 4 for TrioPure™-50 & O3 

Cell 1–O3 Cell 2 for TrioPure™-25)

Содержание TrioPure-25

Страница 1: ...San Luis Obispo CA 93401 USA 800 676 1335 Fax 805 541 8459 110105 4 0777 Rev J Installation and Operation Manual TrioPure 25 TrioPure 50 TrioPure Soft Water Ozone Sanitation System...

Страница 2: ...rioPure must be installed in an outdoor location or indoors in a well ventilated room and installed so that it is level and the orientation is as shown in Figures 1 2 This product manufactures chlorin...

Страница 3: ...3C Where to Get Salt 7 3D How Much Salt to Use 7 3E How to Add Salt 7 3F Pool Sizing Chart 7 3G Salt Sizing Table 8 3H When to Add Salt and Stabilizer 9 SECTION 4 Operation 4A Initial Start Up Procedu...

Страница 4: ...Ozone is made by drawing air through Corona Discharge CD cells that break down oxygen molecules which then recombine into ozone molecules The TrioPure s internal pump pro vides sufficient water flow t...

Страница 5: ...umb so that water from the TrioPure can go into the solar heater Also air bubbles from the solar return must not be allowed into the TrioPure inlet line Either install the bypass mani fold upstream of...

Страница 6: ...ion System DEL Ozone San Luis Obispo CA 93401 USA 800 676 1335 Fax 805 541 8459 2E Plumbing 2e 1 Installing the TrioPureTM Bypass Manifold Do not install the Bypass Manifold with the 2 section in a ve...

Страница 7: ...and non solar heaters Return from TrioPureTM plumbed to a dedicated 1 return to the lowest point of the pool where possible To minimize the size of ozone bubbles use a dispersion cap or main drain cov...

Страница 8: ...tallations where the bypass manifold causes too much flow restriction in the line The spa will be fed sanitized water through the spillway when the system is in pool mode When the system goes into spa...

Страница 9: ...tential fire and or electrical hazard Step 3 Open the front clear cover by removing the screw and opening the latch on the right side of the enclosure Step 4 Remove the front display plate by pulling...

Страница 10: ...alt Capture water from about 18 deep in a container and then test this water sample Add enough salt to obtain a salin ity of approximately 3 500 ppm Refer to Salt Sizing Table Figure 7 on pages 8 9 3E...

Страница 11: ...0 0 0 0 0 0 0 Over 5000 Dilute Dilute Dilute Dilute Dilute Dilute Dilute Dilute Dilute 25 500 26 000 26 500 27 000 27 500 28 000 28 500 29 000 29 500 0 745 759 774 789 803 818 833 847 862 250 692 705...

Страница 12: ...much salt you will need If existing stabilizer levels require it you may also need to add about 1 25 pounds of stabilizer Cyanuric Acid for every 50 pounds of salt added to the pool For example if ad...

Страница 13: ...nd not lit The Low Salt indicator blinks red when the pool should be checked for low salinity Warning always check salinity level with a test strip or digital meter before adding salt 4 High Salt Indi...

Страница 14: ...oPure power switch to ON The model either 25 or 50 will be displayed followed by the firmware revision number Then the display will show the current Chlorine Control setting S B OF Step 7 Observe the...

Страница 15: ...e flow ball on the flow meter does not move to the proper position go to Trouble Shooting Section 6A for assistance Step 9 Turn Chlorine Control knob up about half way pointing straight up Step 10 Obs...

Страница 16: ...ounts of either nitrates or phosphates can have a significant negative impact on the performance of ozone and chlorine in swimming pools If you experience conditions such as cloudy water or algae grow...

Страница 17: ...e submerged Allow the plates to soak for about 30 minutes or until effervescence stops and plates are clean Take care not to let the acid solution into the front chamber of the chlorinator cell as dam...

Страница 18: ...A 800 676 1335 Fax 805 541 8459 2 Disconnect quick disconnect fitting 4 Remove attachment shaft 5 Remove chlorinator cell by turning knob counterclockwise 1 Turn power off 6 Disconnect the two small e...

Страница 19: ...ke on the right side of the enclosure Figure 18 and the air exhaust at the bottom of the enclosure Figure 18 The screen filters are intended to keep insects and debris out of the TrioPureTM unit Allow...

Страница 20: ...00 ppm add salt run the pool pump for 24 hours then check the salt level again Repeat as needed to bring the salt level to within 3 000 to 5 000 PPM B Low Water Temp B Check the pool temperature If th...

Страница 21: ...red until the water temperature is above 59 F C Temperature sensor has become disconnected C Verify connections are correct and secure Problem Cause Solution s A The salt chlorinator is in Cleaning mo...

Страница 22: ...ll service if the main fuse blows repeatedly TrioPureTM Sanitation System 19 Figure 27 Figure 28 Figure 29 DEL Ozone San Luis Obispo CA 93401 USA 800 676 1335 Fax 805 541 8459 A Pool water low salin i...

Страница 23: ...n DEL will arrange for an Authorized Service Center to schedule a service call If a service provider isn t available within a reasonable distance as determined by DEL Ozone the product must be sent to...

Страница 24: ...ALANCE OF THE ORIGINAL WARRANTY PERIOD NOTE USE ONLY DEL OZONE AUTHORIZED REPLACEMENT PARTS USE OF ANY OTHER PART S WILL AUTOMATICALLY VOID THIS WARRANTY THIS LIMITED WARRANTY DOES NOT INCLUDE ANY OF...

Страница 25: ...email Date of Purchase Installed by Name of Company Date of installation Address Phone Number Type of Pool Above ground In ground Fiberglass Vinyl Gunite New Construction Remodeled Pool Retrofit to ex...

Страница 26: ......

Отзывы: