14
TrioPure
TM
Sanitation System
DEL Ozone · San Luis Obispo, CA 93401 · USA · 800-676-1335 · Fax: 805-541-8459
5D
TrioPure
TM
Maintenance
5d-1 Chlorinator Cell Plate Cleaning
Option 1
- (Acid Solution Injection) Adjust Chlorine Control knob
to min. The display should read
“OF”
. Prepare a solution of four
parts water to one part Muriatic Acid. Check the chlorinator cell
for bubbles at the injector. Disconnect the ozone line going into
the chlorinator cell. Connect the acid injection line to the line
going into the chlorinator cell. Place the other end of the Acid
Injection Line into the acid solution. Observe that the solution is
being drawn up into the chlorinator cell. When the scale begins
to fizz, turn the unit off until the fizzing subsides. Repeat until
the scale is completely removed. Disconnect the cleaning kit
and reattach the line to the elbow fitting. Properly clean and
store the acid injection materials.
NOTE:
Take precautions per muriatic acid manufacturer’s
instructions. Wear protective gloves & eyewear and add acid
to water. Never add water to acid.
Option 2
- (acid soaking) Turn off power (at breaker) and water
to the TrioPure™. Remove the chlorinator cell per Section 5d-2.
Remove the union fitting and attach an internal threaded 3/4”
elbow fitting (available at hardware & farm supply stores). Pre-
pare a solution with four parts water for each part muriatic acid.
NOTE: Place the cell on a level surface with the front of the cell
and the open end of the elbow pointing up.
Always add acid to water, never add water to acid. Care-
fully pour acid solution into the elbow fitting just until the
chlorinator cell plates are submerged. Allow the plates
to soak for about 30 minutes, or until effervescence
stops and plates are clean. Take care not to let the acid
solution into the front chamber of the chlorinator cell,
as damage to the flow switch may result.
When the chlorinator cell plates appear to be clean (free of
calcium deposits), pour the acid solution from the chlorinator
cell into the swimming pool.
Figure 16 - Chlorinator Cell Plate Cleaning
5d-2 Chlorinator Cell Removal
Step 1 -
Turn the power off to the TrioPure™
and main pool
circuit breaker. Close the two ball valves (if installed) to the
TrioPure™ and disconnect the union going to the chlorinator cell.
Step 2 -
Disconnect the Ozone Line fitting on the lower
left side of the TrioPure™ by rotating the fittings halves
in opposite directions and separate the two halves.
Step 3 -
Remove the two electrical terminals by loosening
the small hand knobs on the right side of the chlorinator cell,
removing the 7/16” nuts then slipping the terminal lugs off the
connector studs.
Note the order of disassembly and reverse for
reassembly.
Step 4 -
Remove the left side attachment shaft by unscrewing
the hand knob.
Step 5
- With one hand supporting the chlorinator cell in the
middle, unscrew the right side attachment knob. As this knob
is unscrewed, the chlorinator cell will lower.
Use caution and do not allow the weight of the chlorinator cell
to stress the wires on the electrical connectors.
Step 6
- With the chlorinator cell now mechanically detached,
access the two small electrical connectors for the flow switch
and the temperature sensor and disconnect these connectors
from the chlorinator cell. The connectors have a locking feature
that must be raised to separate the connector plug and socket.
Remove the chlorinator cell from the TrioPure
TM
enclosure.
Figure 15 - Acid Injection line
Содержание TrioPure-25
Страница 26: ......