background image

IMPORTANT SAFETY INSTRUCTIONS

Read and Follow All Safety Instructions

Read and be familiar with this manual before installing, operating or performing maintenance on the TrioPure

TM

.

The TrioPure

TM

 must be installed and operated as specified in Section 2 of this manual.

When installing and using this electrical equipment, basic safety precautions must always be followed. 

To reduce risk of electrical shock, turn off main pool pump and disconnect power to pool equipment prior to any installation or 

removal of TrioPure

TM

 components.

All permanent electrical connections should be made using liquid tight fittings and conduit and be made by a certified electrician. 

A ground terminal marked:            is located inside the compartment.  To reduce the risk of electric shock, this terminal must be 

connected to the grounding means provided in the electrical supply service panel with a continuous copper wire equivalent in 

size to the circuit conductors supplying this equipment.

A bonding lug is provided on the external surface of the TrioPure

TM

.  To reduce the risk of electric shock, connect the local common 

bonding grid in the area of the swimming pool, spa or hot tub to these terminals with a copper conductor not smaller than 8 AWG 

for US and 6 AWG for Canadian installations.

A Ground Fault Circuit Interrupter 

(

GFCI) must be installed between the TrioPure™ and the electrical supply.

Mount the TrioPure™ so that it is inaccessible to anyone in the pool. Never attempt any servicing while unit is wet.

The TrioPure

TM

 must not be installed directly above any heat source (e.g., heater). It must be at least 2 ft. (600 mm) above the 

ground to allow free circulation of air around it. It must not be installed in a closed box. 

The TrioPure™ must be installed in an outdoor location, or indoors in a well-ventilated room, and installed so that it is level and 

the orientation is as shown in Figures 1-2.

This product manufactures chlorine. Individuals with any type of chlorine sensitivity should take the appropriate precautions to 

avoid injury or illness.

To avoid personal injury when working with pool chemicals, always wear rubber gloves and eye protection and work in a well-

ventilated area. Use caution when choosing a location to open and use chemicals as they may damage any surface in which 

they come in contact.  

For your safety, do not store or use gasoline, chemicals or other flammable liquids or vapors near this or any other appliance.

Do not let anyone, especially small children, sit, step, lean or climb on any equipment installed as part of your pool’s operational 

system. 

WARNING: 

Always dilute acid in a bucket of pool water before adding to the pool. Never add water to acid, always add chemicals 

to water. Carefully follow acid manufacturer’s safety precautions. DO NOT MIX DIFFERENT CHEMICALS TOGETHER.

WARNING: 

Short-term inhalation of high concentrations of ozone and long-term inhalation of low concentrations of ozone can 

cause serious harmful physiological effects.  DO NOT inhale ozone gas produced by this device.

WARNING: 

Excessive chlorine levels can cause corrosion damage to swimming pool rails, ladders, heaters,  heat exchangers, 

light faceplates and other metallic equipment. Avoid over saturation of chlorine levels by checking chlorine often using a suitable 

chlorine test device. Chlorine levels should not exceed 3 ppm.  Always check chlorine levels before entering pool.

WARNING:

 To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all 

times.

SAVE THESE INSTRUCTIONS!

TrioPure

TM

 

Sanitation System

DEL Ozone · San Luis Obispo, CA 93401 · USA · 800-676-1335 · Fax: 805-541-8459

i

Содержание TrioPure-25

Страница 1: ...San Luis Obispo CA 93401 USA 800 676 1335 Fax 805 541 8459 110105 4 0777 Rev J Installation and Operation Manual TrioPure 25 TrioPure 50 TrioPure Soft Water Ozone Sanitation System...

Страница 2: ...rioPure must be installed in an outdoor location or indoors in a well ventilated room and installed so that it is level and the orientation is as shown in Figures 1 2 This product manufactures chlorin...

Страница 3: ...3C Where to Get Salt 7 3D How Much Salt to Use 7 3E How to Add Salt 7 3F Pool Sizing Chart 7 3G Salt Sizing Table 8 3H When to Add Salt and Stabilizer 9 SECTION 4 Operation 4A Initial Start Up Procedu...

Страница 4: ...Ozone is made by drawing air through Corona Discharge CD cells that break down oxygen molecules which then recombine into ozone molecules The TrioPure s internal pump pro vides sufficient water flow t...

Страница 5: ...umb so that water from the TrioPure can go into the solar heater Also air bubbles from the solar return must not be allowed into the TrioPure inlet line Either install the bypass mani fold upstream of...

Страница 6: ...ion System DEL Ozone San Luis Obispo CA 93401 USA 800 676 1335 Fax 805 541 8459 2E Plumbing 2e 1 Installing the TrioPureTM Bypass Manifold Do not install the Bypass Manifold with the 2 section in a ve...

Страница 7: ...and non solar heaters Return from TrioPureTM plumbed to a dedicated 1 return to the lowest point of the pool where possible To minimize the size of ozone bubbles use a dispersion cap or main drain cov...

Страница 8: ...tallations where the bypass manifold causes too much flow restriction in the line The spa will be fed sanitized water through the spillway when the system is in pool mode When the system goes into spa...

Страница 9: ...tential fire and or electrical hazard Step 3 Open the front clear cover by removing the screw and opening the latch on the right side of the enclosure Step 4 Remove the front display plate by pulling...

Страница 10: ...alt Capture water from about 18 deep in a container and then test this water sample Add enough salt to obtain a salin ity of approximately 3 500 ppm Refer to Salt Sizing Table Figure 7 on pages 8 9 3E...

Страница 11: ...0 0 0 0 0 0 0 Over 5000 Dilute Dilute Dilute Dilute Dilute Dilute Dilute Dilute Dilute 25 500 26 000 26 500 27 000 27 500 28 000 28 500 29 000 29 500 0 745 759 774 789 803 818 833 847 862 250 692 705...

Страница 12: ...much salt you will need If existing stabilizer levels require it you may also need to add about 1 25 pounds of stabilizer Cyanuric Acid for every 50 pounds of salt added to the pool For example if ad...

Страница 13: ...nd not lit The Low Salt indicator blinks red when the pool should be checked for low salinity Warning always check salinity level with a test strip or digital meter before adding salt 4 High Salt Indi...

Страница 14: ...oPure power switch to ON The model either 25 or 50 will be displayed followed by the firmware revision number Then the display will show the current Chlorine Control setting S B OF Step 7 Observe the...

Страница 15: ...e flow ball on the flow meter does not move to the proper position go to Trouble Shooting Section 6A for assistance Step 9 Turn Chlorine Control knob up about half way pointing straight up Step 10 Obs...

Страница 16: ...ounts of either nitrates or phosphates can have a significant negative impact on the performance of ozone and chlorine in swimming pools If you experience conditions such as cloudy water or algae grow...

Страница 17: ...e submerged Allow the plates to soak for about 30 minutes or until effervescence stops and plates are clean Take care not to let the acid solution into the front chamber of the chlorinator cell as dam...

Страница 18: ...A 800 676 1335 Fax 805 541 8459 2 Disconnect quick disconnect fitting 4 Remove attachment shaft 5 Remove chlorinator cell by turning knob counterclockwise 1 Turn power off 6 Disconnect the two small e...

Страница 19: ...ke on the right side of the enclosure Figure 18 and the air exhaust at the bottom of the enclosure Figure 18 The screen filters are intended to keep insects and debris out of the TrioPureTM unit Allow...

Страница 20: ...00 ppm add salt run the pool pump for 24 hours then check the salt level again Repeat as needed to bring the salt level to within 3 000 to 5 000 PPM B Low Water Temp B Check the pool temperature If th...

Страница 21: ...red until the water temperature is above 59 F C Temperature sensor has become disconnected C Verify connections are correct and secure Problem Cause Solution s A The salt chlorinator is in Cleaning mo...

Страница 22: ...ll service if the main fuse blows repeatedly TrioPureTM Sanitation System 19 Figure 27 Figure 28 Figure 29 DEL Ozone San Luis Obispo CA 93401 USA 800 676 1335 Fax 805 541 8459 A Pool water low salin i...

Страница 23: ...n DEL will arrange for an Authorized Service Center to schedule a service call If a service provider isn t available within a reasonable distance as determined by DEL Ozone the product must be sent to...

Страница 24: ...ALANCE OF THE ORIGINAL WARRANTY PERIOD NOTE USE ONLY DEL OZONE AUTHORIZED REPLACEMENT PARTS USE OF ANY OTHER PART S WILL AUTOMATICALLY VOID THIS WARRANTY THIS LIMITED WARRANTY DOES NOT INCLUDE ANY OF...

Страница 25: ...email Date of Purchase Installed by Name of Company Date of installation Address Phone Number Type of Pool Above ground In ground Fiberglass Vinyl Gunite New Construction Remodeled Pool Retrofit to ex...

Страница 26: ......

Отзывы: