TrioPure
TM
Sanitation System
DEL Ozone · San Luis Obispo, CA 93401 · USA · 800-676-1335 · Fax: 805-541-8459
16
Figure 18
Figure 19
Figure 20
Air Exhaust Screen Filter:
The Air Exhaust Screen Filter should typically not require
servicing. After removing the Chlorinator Cell (See Sec-
tion 5d-2), visually check the filter for debris. If the filter
appears to require cleaning then remove plastic filter
keeper by lightly prying it out. Remove the screen filter,
clean and replace.
5d-3 Air Filters
The TrioPure
TM
has screen filters located at both the
cooling fan air intake on the right side of the enclosure
(Figure 18) and the air exhaust at the bottom of the
enclosure (Figure 18). The screen filters are intended
to keep insects and debris out of the TrioPure
TM
unit.
Allowing these screen filters to become clogged could
result in the TrioPure
TM
shutting down to protect from
overheating. Annual inspection and cleaning of the
screen filters is recommended as follows:
Air Intake Screen Filter:
Turn off power to the TrioPure
TM
. Remove the cover
by sliding the cover up (Figure 19). Once the cover
is removed visually check the filter for debris. If the
filter appears to require cleaning, carefully remove
plastic filter keeper (Figure 20) by lightly prying it out.
Remove the screen filter and clean it. Replace filter,
keeper and cover.