8
2.2
Operating principle "Active mode"
Pool monitoring during bathing hours
For pool monitoring during bathing hours the active mode
must be
activated. (For how to activate, see
page 18
).
For each swimming pool user, a monitoring bracelet is pre-programmed with a
personal alarm depth and alarm time – according to the user’s swimming ability.
Programming is carried out using the PC program BlueFox Control (see
Program-
ming the alarm depth and time, P. 34
).
When the user enters the water the monitoring bracelet automatically switches on
(water contacts).
Course of events when an alarm sounds
At depths greater than the alarm depth and when the programmed alarm time
expires, the monitoring bracelet activates the Alarm
2
. The pool sensor receives
the alarm signal and routes it to the alarm box. The following alarms are triggered:
Warning lights and sirens,
STD
PRO
radio alarm.
Warning
!
Risk of drowning! Initiate rescue immediately alarm sounds.
Swimming pool
Alarm depth
Depth profile
Monitoring bracelet
Time
Depth
2
4
1
Programmed
alarm time
Warning lights
3
Siren
The siren is deactivated by
pressing any button on the
alarm box
The siren can be deactivated by pressing any button on the alarm box
3
. The
following alarms remain active until the monitoring bracelet is taken out of the
water
4
: Warning lights,
STD
PRO
radio alarm.