![Deep Blue Basic Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/deep-blue/basic/basic_installation-and-operating-instructions-manual_2463057029.webp)
29
9
Testing passive mode
Warning
!
Risk of drowning because the BlueFox system is not monitoring the pool.
If the passive mode LED is flashing BlueFox is not monitoring the pool.
The pool must be monitored by a person.
Caution!
Risk of hearing damage caused by the sound pressure level from the
siren! Wear hearing protection; keep children away from the siren.
Immediately press any button on the alarm box once the siren sounds.
y
Using adhesive tape, fasten together four 1.5 litre plastic bot-
tles filled with water to form a 6kg weight.
y
Secure an approx. 2 m long line to the weight. This line is
used to pull the weight out of the water again after the test.
y
Activate passive mode,
page 27
y
As soon as the waves have subsided (after approx. 12 min-
utes), the passive mode LED will illuminate permanently.
y
Holding the end of the line in your hand, throw the 6kg
weight into the water from the edge of the swimming pool.
The alarm must activate after a maximum of 12 seconds.
y
Once an alarm is triggered the siren will sound and the warning lights and LED
alongside the -switch will flash. Once the siren sounds press any button im-
mediately. The alarm will be deactivated.
y
Pull the weight out of the swimming pool.
y
As soon as the waves have subsided (after approx. 12 minutes), the passive
mode LED will illuminate permanently.
y
Repeat the test at other positions in the swimming pool (corners, niches).
y
If the test was only partially successful or not successful at all: See
Troubleshoot-
ing, P. 42