Connect up the nine screw terminals on the power supply
Plug the second of the two yellow power
lines into the terminal with the letter N
above it and tighten the screw.
Plug the green Earth cable into the
terminal with the Earth symbol above it
and tighten the screw.
Plug the black wire for the fan power supply
line into the fourth terminal from the left,
which has COM above it. Put the pink wire
into the seventh terminal, which has +V
above it. Tighten the screws.
5
6
7
Black
wire
Pink
wire
Earth symbol
3
There are nine screw terminals on the end of the power supply. Use a size 2 Phillips screwdriver to
loosen them all before you start attaching cables.
9 screw
terminals
Gap when
screw is
loosened
When you insert
the Y-shaped end of a cable
into a screw terminal, do it so
the crimp mark is uppermost
so it goes in securely.
4
Plug the Y-shaped end of one of the yellow power lines into the terminal on the left with the
letter L above it. Tighten the screw of the terminal with the screwdriver.
Plug in
Crimp
mark