page B40
DS-100C Operating Manual
Appendix B DS-Tracer ERROR CODES
ERROR
10
“I/O ERROR”
RS-232 serial communications error. Baud rate, parity, number of data
bits, or number of stop bits is incorrect. DS-Tracer uses 9600 baud, no
parity, 8 data bits, and 1 stop bit.
ERROR
13
“UNKNOWN COMMAND”
Command is not recognized by the DS-Tracer . This may be due to a
syntax error.
ERROR
14
“BUFFER OVERFLOW”
Internal command line buffer overflow. Total number of characters in
command line cannot exceed 255.
ERROR
15
“COMMAND LINE OVERFLOW”
A command has been sent to the DS-Tracer before the previous
command has finished. Wait for return prompt.
ERROR
16
“PARAMETER TOO LONG”
The maximum length of any command line parameter is 15 characters.
ERROR
17
“TOO MANY PARAMETERS”
A maximum of 16 parameters (including command code) are allowed.
ERROR
30
“OVER MAXIMUM VOLTAGE”
The take I-V curve command cannot continue because the PV system
voltage exceeds the maximum voltage range (this PV system cannot be
tested with the DS-Tracer ).
ERROR
31
“OVER LOW VOLTAGE RANGE”
The take I-V curve command cannot continue because the PV system
voltage exceeds the low voltage range (switch to high voltage range).
Содержание DS-100c
Страница 8: ......