DS-100C Operating Manual
page B41
ERROR
32
“INPUT LESS THAN OR EQUAL ZERO VOLTS”
The take I-V curve command cannot continue because the PV system
voltage is less than or equal to 0 V. Check PV system and DS-Tracer
disconnect switches. This error can also be caused by a reverse polarity
on the DS-Tracer to PV system connection.
ERROR
40
“DISCONNECT SWITCH IS OFF”
The DS-Tracer is trying to take an I-V curve, but the DS-Tracer
DISCONNECT switch is off.
ERROR
50
“INVALID NUMERIC PARAMETER”
Parameter must represent valid numeric value.
ERROR
60
“INVALID ANALOG I/O CHANNEL #”
The DS-Tracer accepts channel numbers 0 through 13.
ERROR
63
“DSP ERROR”
DS-Tracer DSP board has an error. Usually an A/D has failed or the
connect to the DSP board has failed.
ERROR
“UNKNOWN ERROR”
Some type of unknown error has occurred. Check parameters for proper
syntax.
Содержание DS-100c