DS-100C Operating Manual
page C23
Transportation
Treat the DS-Tracer as you would a notebook computer. The DS-Tracer is
mounted in a heavy-duty case but this is
NOT
adequate to ship the unit as freight
without using a shipping container. Because of its weight, it will likely be
damaged if it is dropped or tossed. Due to airline security, Daystar does not
recommend attempting to carry the tracer on board a commercial airplane as
carry-on baggage A shipping container with foam packing is supplied as
standard equipment with all DS-100C curve tracers. Daystar strongly
recommends using this case anytime the DS-100C is shipped.
DS-Tracer Fuses
The DS-Tracer has three externally accessible fuses. The first of the external
fuses is located in the AC input power receptacle. Power line surges or internal
faults can cause this fuse to fail. Return the DS-Tracer for repairs if this fuse
blows repeatedly. Replace this fuse with the type indicated on the DS-Tracer
panel.
A user accessible fuse is located on the front panel and is labeled “PRE-
CHARGE” fuse. This
1/4 Amp, fast-blow fuse
protects the DS-Tracer pre-
charge circuitry. See section 5.0 Pre-Charge Precautions for more details. This
fuse may blow if the DS-Tracer connection and disconnection sequences are not
followed exactly. Replace only with a
1/4 Amp, fast-blow fuse
.
A third user replaceable fuse is the
2 Amp, fast-blow DC charging fuse
. This
fuse should only blow if a DC source voltage exceeds the rating on the DS-
Tracer panel. Replace only with a
2 Amp, fast-blow DC charging fuse.
There is an internal fuse on the power supply board battery circuit. This fuse is
installed as protection when the DS-Tracer is removed from its case during
repairs. Contact Daystar, Inc. if you suspect that this fuse has blown.