Safety Precautions While Using
»
When using heaters, the requirements of technical regulations, construction,
plumbing, fire regulations and standards must be met.
»
The heater must be grounded. The heater is not allowed to be turned on without
grounding.
»
It is not allowed to operate the device with damaged ceramic tiles.
»
The heater should be mounted on non-combustible structures.
»
If there is a gas smell in the room, it is forbidden to open the device.
»
The place where the heater works must be equipped with fire extinguishing
equipment in accordance with fire safety requirements.
»
When used outdoors, the heater should be protected from precipitation and wind.
»
It is forbidden to touch the boiler, the burner, the reflector and the casing of the
device while the heater is operating and within a few minutes after it is turned off.
(until the heated parts have cooled down completely).
Gas and Electricity Connection
Considerations
Gas Connection
The gas connection of the device must be made by persons authorized and
certified by the distribution company.
The gas line must have a pressure of 20 - 50 mbar. The pressure must be
checked before the gas connection.
Electrical Connection
After the device is installed, make sure to measure your electrical line before
energizing the device.
Before energizing the device, make sure that the grounding line is in your
power line. Make sure it is. Never give electricity to the device without a
grounding line.
The electrical connection of the device is in the form of a C-14 socket. Do not
make the connection with any cable other than the power cable that comes
out of the device and do not cut the existing power cable.
Before giving electrical energy to the device, make sure to measure your
electrical line. Our device works with 220/230 V 50 Hz. In case these values
change and there is interference, make sure to stabilize your line with
regulatory devices.