background image

First Run

26

www.daygas.eu

 

»

Make sure that the device is made according to the mounting dimensions and that 

the mounting is solid.

 

»

Make sure that the gas connection of your device is made correctly and that there 

is no gas leakage.

 

»

Make sure that the electrical connection of your device is correct.

 

»

Before operating the device, open the gas valve.

 

»

Supply electrical energy to your device. After energizing (--) on the step screen it 

will burn. Turn on the device by pressing the on-off button of your remote control.

 

»

After starting your device, you can switch between the levels by using the       keys             

of your remote control. You can turn off your device with the on-off button on the 

remote control.

 

»

If your device goes into malfunction mode, E1 or E2 will light on the information 

screen on the device. In this case, be sure to check the gas connection and the 

electrical connection. After the faults are resolved, when you press the onn-off 

button of your remote, the device will reset itself and be ready to work again.

Troubleshooting

 

»

My device does not fire, the light on the information screen on the device does not 

turn on!

Check the electrical connection of your device.

 

»

My device ignites but does not catch fire!

Check the gas connection of your device.

 

»

My device does not switch between levels, does not turn on or off!

Check your remote control and battery.

 

»

E1-E2 symbol lights up on the information screen on my device, I cannot intervene 

from the remote!

Check the gas and electricity connection of your device. If there is no problem or after 

the faults are resolved, press the on-off button of your remote. After the (O) symbol 

appears on the information screen on the device, you can operate your device again.

 

»

My device suddenly shuts down while working!

Check the electrical connection and grounding line of your device. Check that the 

amount of oxygen in the environment where the device is located is sufficient.

Check whether your device receives high pressure wind. Check that the gas 

connection of your device and the pressure of the gas line are correct.

For malfunctions of your device other than the ones described above, please contact 

the manufacturer of the device and the service without intervening. Interfering with 

malfunctions other than the ones above may have dangerous consequences.

Содержание Radium 15

Страница 1: ...TUBE RADIANT HEATER USER MANUAL AND WARRANTY CERTIFICATE Daygas Heating Systems n Tah Ltd Sti Firuzk y Bulvar No 206 34325 Avcilar Istanbul 0 850 532 91 53 0 212 423 30 44 Avcilar VD 2710796836 MANUFA...

Страница 2: ...eries Purpose Usage Areas 15 Ignition Electrode Prosestat Snail Fan Snail Fan Technical Specifications Radium U Type Products Equipment 11 12 13 Step 2 Step 3 19 Radium U Type Assembly Steps Step 1 St...

Страница 3: ...Our company has been operating since 2014 and has been operating in production sale and aftersales activities of ceramic fillet heaters industrial ceramic fillet heaters hot air generators pipetype f...

Страница 4: ...al places zones and sites Buildings structures and soil in the process of construction of buildings and structures For technological heating of materials and equipment Usage Areas of Radium Tubular Se...

Страница 5: ...rea of the device it must be checked whether it is suitable for the usage pressure It should be used by making the necessary settings The device should never be operated without providing the necessar...

Страница 6: ...tion Dimensions mm Weight kg Installation Height kW m h NG m h LPG H L W Net Gross CM Radium 15 15 1 43 1 05 250 4200 405 65 80 250 450 Radium 20 20 1 90 1 41 250 4200 405 65 80 250 450 Radium 30 30...

Страница 7: ...0 3 400 4 230 1 Normal close 50 0 7 15 60 G3 4 1 115 x 65 x 93 Ignition Electrode Technical Specifications PARAMETER VALUE Power source V Current frequency Hz Consumed electrical power VA Excluding t...

Страница 8: ...ustion process by sending the gas it receives from the gas valve to the mixing pipes with a flex There are spark plugs with flame sensors where the flame occurs Spark plugs and flame sensors are conne...

Страница 9: ...should be done by Daygas Authorized Service Before connecting the valve block to the gas pipeline the gas pipeline must be cleaned and degassed Gas valve and natural gas line connection should be mad...

Страница 10: ...le inlet changes by slowly turning the screw of the adjustment pressure regulator to the right and left The pressure setting of the device is adjusted according to the data on the information label Af...

Страница 11: ...the air temperature is broken the devices do not work 11 www daygas eu The ignition unit is a high voltage spark plug combined with a flame sensor ionization sensor in a housing The ignition block ha...

Страница 12: ...nufactured in an aerodynamic structure that will provide airfoil and regular flow It operates silently thanks to its aerodynamic wing structure It is designed to be maintenance free for a long time It...

Страница 13: ...Radium U Type Device Equipment REFLECTOR COVER U ELBOW RADIANT PIPE REFLECTOR LOWER HANGER BURNER FLUE OUTLET BURNER TOP HANGER 13 www daygas eu...

Страница 14: ...g It should be hung flat on the scale leaving a gap of 280 cm between the lower hanger apparatus The lengths of all the stalactites must be in the same proportion and straight The space between the de...

Страница 15: ...ull contact with the radiant pipes in the U elbow assembly Be sure and provide the connection with stainless couplings After tightening make sure to check that the compression is correct and firm If n...

Страница 16: ...ting points on the lower hanger apparatus Be sure to check whether there is any stretching or vibration after assembly Step 7 Final Check of Device After all the assembly steps are completed make the...

Страница 17: ...0 105 260 470 Radium 35 35 3 33 2 46 250 6900 9900 12900 260 60 85 110 80 105 150 280 800 Radium 40 40 3 80 2 81 250 9900 12900 15900 260 85 110 135 105 150 185 300 900 Radium 45 45 4 28 3 16 250 9900...

Страница 18: ...minimum 30 kg carrying capacity It should be hung flat on the scale leaving a gap of 280 cm between the lower hanger apparatus The lengths of all the stalactites must be in the same proportion and str...

Страница 19: ...square and aligned Step 3 Burner Assembly Make sure that the burner pipe is in full contact with the radiant pipe and fix it with a stainless coupling After fixing make sure that the burner is level a...

Страница 20: ...paratus Make the adjustment so that the compression springs on the suspension apparatus are in full contact with the reflector Step 5 Final Check of Device After all the assembly steps are completed m...

Страница 21: ...Radium Tube Type Gas and Electric Connections of Devices 1 Electrical Connection Socket 190 260 V 50 60 Hz 2 Gas Connection 3 4 Gas Pressure 20 50 mbar 21 www daygas eu 1 2...

Страница 22: ...lex connected to the device is G3 4 Make sure that there is grounding in the electrical installation Grounding is required Commissioning Procedure CAUTION Person who commissioned Radium Tubular heater...

Страница 23: ...not start within 30 seconds the gas supply to the emitter is cut off To restart the transmitter you must turn off the transmitter s power supply Connect the power cable to the transmitter via an exte...

Страница 24: ...an the outer surfaces from dust and dirt wipe the reflective surfaces of the reflectors with a dry and soft cloth Clean the inside of the heater by blowing compressed air at a pressure of 0 4 0 5 MPA...

Страница 25: ...have cooled down completely Gas and Electricity Connection Considerations Gas Connection The gas connection of the device must be made by persons authorized and certified by the distribution company...

Страница 26: ...e the light on the information screen on the device does not turn on Check the electrical connection of your device My device ignites but does not catch fire Check the gas connection of your device My...

Страница 27: ...burns caused by contact with the device Check the gas connection of your device against gas leakage Do not interfere with your device with bare hands Make sure that the flammable part of your device...

Страница 28: ...28 GUARANTEE CERTIFICATE...

Страница 29: ...repair The consumer may request the return of the goods a reduction in the price at the rate of defects or if possible the replacement of the goods with a non defective one from the seller The seller...

Страница 30: ...ce heating 5 In case the device s are first started up outside of Daygas Heating Systems or Daygas authorized service 6 In case of malfunctions and damages arising from electrical voltage fluctuations...

Страница 31: ...31...

Страница 32: ...Brand Model Serial Number Authorized Service Title Address Phone Number Fax E Mail Authorized Stamp Yetkili Signature Seller Company MANUFACTURER Title Address Phone Number Fax E Mail Authorized Stamp...

Страница 33: ...sioning Date Of The Product MANUFACTURER Daygas Heating Systems n Tah Ltd Sti Firuzk y Bulvar No 206 34325 Avcilar Istanbul 90 850 532 91 53 90 212 423 30 44 Avcilar VD 2710796836 Title Address Phone...

Страница 34: ...325 Avcilar Istanbul 90 850 532 91 53 90 212 423 30 44 info daygas eu www daygas eu MANUFACTURER Daygas Heating Systems n Tah Ltd Sti Firuzk y Bulvar No 206 34325 Avcilar Istanbul 0 850 532 91 53 0 21...

Отзывы: