Technical Maintenance
The maintenance and operation of the heater should be done in the following cases.
»
During commissioning.
»
When changing from one type of gas to another.
»
After entering storage mode in case of seasonal use, before operating.
»
After troubleshooting.
»
At least once a year, regardless of the technical situation.
CAUTION! The person who maintains the heater and checks its operation;
»
Read this guide.
»
The person who maintains the heaters and controls their operation
‘‘Security
Rules for Consumption Networks’’
must have knowledge and certificate.
»
The person who maintains and ensures the operation of the heaters must have
knowledge of
electrical safety.
Performed During Maintenance List of
Required Activities
»
Perform an external inspection to determine the mechanical damage to the device,
open the intervention cover of the device and make sure that there are no cracks
or damage.
»
Check the condition of the ignition rods for signs of damage from exposure to high
temperatures.
»
Ensure timely replacement of defective parts. prevent the heater from working
make sure there are no foreign objects.
»
Clean the outer surfaces from dust and dirt, wipe the reflective surfaces of the
reflectors with a dry and soft cloth.
»
Clean the inside of the heater by blowing compressed air at a pressure of 0.4-
0.5 MPA through a 3 mm nozzle. Blow through the openings of the tiles from the
outside, then from the inside through the opening of the mixing tube. Evacuate to
run until there is no dust exit from the heater. The frequency of cleaning the interior
depends on the degree of dust in the room.
Attention! In seasonal usage conditions of the heater, the device is not inactive
for a long time.R emains, it is recommended to cover the hole in the mixing tube
with cloths or take various measures to prevent insects and other organic matter
from getting in.
»
Check all electrical connections, check the grounding of the device.
»
Check the tightness of all threaded connections of the heater and gas pipeline.
»
Check the operation of the gas valve, adjust the gas pressure in front of the burner
nozzle if necessary, make sure that both pressure control nipples are tight.
»
Check the operation of automation and security systems. Clean the inside of the
heater by blowing compressed air at a pressure of 0.4-0.5 MPA through a 3 mm
nozzle.
»
Perform the test run of the heater, make sure the device is in good condition.
24
www.daygas.eu
Содержание Radium 15