pag
. 25
DA1000V VOLUMETRIC MANUAL DISPENSING SYSTEM
Figure 22. Interval Mode
8.1.3 INTERVAL MODE
CATEGORY
Shows the set dispensing volume
VOLUME
TIME
SPEED
SUCKBACK
TOTAL CH
COUNT
Displays the set dispensing (ON) time
Displays the set idle (OFF) time
Shows the SPEED value according to the dispensing volume and duration
Shows the set number of SUCKBACK steps
Shows the number of dispenses executed.
- Displays the current count number when dispensing in INTERVAL MODE.
- COUNT value increases by the set number of TOTAL CH. when the dispensing signal is ON.
DESCRIPTION
NANO PENNANOPEN Operation Manual
Doc. Rev 0
2019/7/2
31/47
Copyright © 2019 by TAEHA CORP. All Rights Reserved
7.1.3
INTERVAL MODE
Interval Mode is a Dispensing Mode used to consecutively dispense in Time Mode.
When selected, the equipment alternates between Dispensing ON/OFF, and during the ON signal, material
will be dispensed according to the set TOTAL CH. Additionally, the INTERVAL MODE will stop if the
dispensing signal is provided once again while INTERVAL MODE is in progress.
TIME S TDY INTV S EQ
TOTAL CH.
10
cc
cc
COUNT
S UCKBACK
cc/sec
sec
ON
OFF
2019.01.21 14:59:59
Figure 22. Interval Mode
Category
Description
VOLUME
Shows the set dispensing volume
TIME
Displays the set dispensing (ON) time
Displays the set idle (OFF) time
SPEED
Shows the SPEED value according to the dispensing volume and
duration
SUCKBACK
Shows the set number of SUCKBACK steps
COUNT
- Displays the current count number when dispensing in INTERVAL
MODE.
- COUNT value increases by the set number of TOTAL CH. when the
dispensing signal is ON.
TOTAL CH.
- Shows the number of dispenses executed.
7.1.4
SEQUENCE MODE
Interval Mode is a Dispensing Mode used to consecutively dispense in Time Mode.
When selected, the equipment alternates between Dispensing ON/OFF, and during the ON signal, material will be dispen-
sed according to the set TOTAL CH. Additionally, the INTERVAL MODE will stop if the dispensing signal is provided once