M7/M7L/M7LT Modular Satellite Modem
Maintenance
M7/M7L/M7LT - Rev. 0.05
3-33
Within Table 3-5 through Table 3-12 are descriptions of the parameters available from the front panel
and entry in detail. The grayed separators delineate column divisions in the area matrix. A gray
highlighted parameter indicates that this parameter is not available unless a preceding parameter is
enabled or set to require those parameters, or optional hardware is installed that uses that particular
parameter. Parameters will also be added as new options are installed. A blue highlighted section
indicates that that parameter is a future option and is not available at the current manual release.
Table 3-5 - Modem (Unit) Parameter Detail
Unit Parameters
Representation
Type
Entry
Description
Status Modem
Locked & Sending, Ok
Read Only Read Only
Mod & Demod Status
Status Redundancy
(Future Option)
Read Only
Future Option
Status Reference
Internal, Ok
Read Only Not changeable
Reference source and status
Status IP Control Port
Connected, 100 Mb Fdx
Read Only Not changeable
IP Control Port Status
Status Station ID
San Jose #56
Alpha
–
Numeric
Entered as ASCII for up to 16
characters
Station Name for user
Status Time
17:24:59
Time
Entered as 24 hour time
format
Current Time
Status Date
09/10/12
Date
Entered current date in
mm/dd/yy format
Current Date
Status Model
M7 Series
Read Only Read from Installed Option
Modem Model Number
Status Controller ID
M7009001A-1r1.00
Read Only Read from Installed Option
ID of Installed Controller in
Slot 0
Status RF 1 ID
M709002A-1r1.00
Read Only Read from Installed Option
Installed Modulator or
Demodulator in RF Slot 1
Status RF 2 ID
M709004A-1r1.00
Read Only Read from Installed Option
Installed Modulator or
Demodulator in RF Slot 2
Status Interface 1 ID
M709018A-1r1.05
Read Only Read from Installed Option
Installed Interface Option in
Interface Slot 1
Status Interface 2 ID
M709013A-1r1.00
Read Only Read from Installed Option
Installed Interface Option in
Interface Slot 2
Status Software Version
2.17s Created Aug 14 2013
Read Only Read from Installed Option
Modem Software Version
Status Hardware S/N
1021004
Read Only Read from Installed Option
Modem Serial Number
Event Log Last Event
Intf Hardware OK
@ 2014-05-15 03:21:00.85
Read Only
Press “Edit” then use the
up/dn arrows to scroll through
the logged events
Log of events based on the
configuration of the Event
menu in each functional area.
Event Log Total Events
18
Read Only
Press “Edit” then “Enter” to
clear the logged events
# of Events logged based on
the configuration of the Event
menu in each functional area.