Maintenance
M7/M7L/M7LT Modular Satellite Modem
2-8
M7/M7L/M7LT - Rev. 0.05
Table 2-5
– BUC power supply options
BUC Power Supply
Input Voltage
BUC Power Supply
Output Voltage
BUC power Supply
Power Rating
BUC power Supply
Max Current
90-264 VAC
24 VDC
100 Watt
4.2 Amps
90-264 VAC
24 VDC
120 Watt
5.0 Amps
90-264 VAC
48 VDC
100 Watt
2.1 Amps
90-264 VAC
48 VDC
150 Watt
3.2 Amps
90-264 VAC
48 VDC
240 Watt
5.0 Amps
20-60 VDC
24 VDC
100 Watt
4.2 Amps
20-60 VDC
24 VDC
120 Watt
5.0 Amps
20-60 VDC
48 VDC
100 Watt
2.1 Amps
20-60 VDC
48 VDC
150 Watt
3.2 Amps
20-60 VDC
48 VDC
200 Watt
4.2 Amps
NOTE:
DC Power Input is isolated so it can be either positive or negative ground;
NOTE:
All M7LT DC units are shipped from the factory with a five foot 3-conductor cable with mating
connector on one end that will allow connection to the main DC supply at the installation site.
CAUTION!: VERY important that the polarity needs to be wired correctly
2.3.7.
The Modem External Reference Input at female BNC (J1)
The modem External Ref Input is located on a 50
female BNC J1. The 1, 5, 9 or 10 MHz input
frequency of this interface is programmable from any control interface. A sine wave input level of +10
to
–15 dBm is required for normal operation. Please refer to the specifications in Appendix A