![Datum Systems M7 Series Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/datum-systems/m7-series/m7-series_installation-and-operation-manual_514098033.webp)
M7/M7L/M7LT Modular Satellite Modem
Maintenance
M7/M7L/M7LT - Rev. 0.05
2-1
Installation
2.0
Installation Requirements
The M7 Modem is designed for installation in any standard 19-inch equipment cabinet or rack, and
requires 1 RU mounting space (1.75 inches) vertically and 12 inches of depth (not including cabling
space) but only one half of the rack space in width. The M7 is shipped with an external IEC filtered
AC to DC power converter module designed to accept a 3-wire AC line cord and plug suitable for the
country of operation. Installation and connection to the AC power line must be made in compliance to
local or national wiring codes and regulations. The M7 may be placed on a table or suitable stable flat
surface as required.
CAUTION!: There are no user-serviceable parts or configuration settings located inside the M7
modem chassis. When option card installation is to be done, DO NOT open the
modem case unless prime power is removed.
CAUTION!: Before initially applying power to the modem, it is a good idea to disconnect the
transmit output from the operating satellite ground station equipment. This is
especially true if the current modem configuration settings are unknown, where
incorrect setting could disrupt existing communications traffic.
2.1.
Unpacking
The M7 Modem was carefully packed to avoid damage and should arrive complete with the following
items for proper installation:
M7 Modem Unit, L-Band Units may include an external BUC power supply.
IEC filtered AC to DC power converter module with a six foot power cord
Installation and Operation Manual plus other information on CD.
2.1.1.
Removal and Assembly
If using a knife or cutting blade to open the carton, exercise caution to ensure that the blade does not
extend into the carton, but only cuts the tape holding the carton closed. Carefully unpack the unit and
ensure that all of the above items are in the carton. If the Prime AC power available at the installation
site requires a different power cord/AC connector, then arrangements to receive the proper device will
be necessary before proceeding with the installation.
The M7 Modem unit is shipped fully assembled and does not require removal of the covers for any
purpose in normal installation. All normal hardware configuration, including setting the data interface
type and IF impedance is under software control. The type of Feature Sets, FEC Options and
Interface Options installed can be read from the LCD display on the front panel under
<Unit: Status>
column by scrolling down after initial application of power.
Should the power cable AC connector be of the wrong type for the installation, either the cable or the
power connector end should be replaced. The power supply itself is designed for world-wide
application using from 90 to 264 VAC (100 to 240 VAC +/- 10%).
2.2.
Mounting Considerations
When mounted in an equipment rack, adequate ventilation must be provided. The ambient
temperature in the rack must be between 0
and 50
C, and held constant for best equipment
operation. The air available to the rack should be clean and relatively dry. The modem units may be
stacked one on top of the other to a maximum of 10 consecutive units before providing a 1 RU space
for airflow. Modem units should not be placed immediately above a high heat or EMF generator to
ensure the output signal integrity and proper receive operation.