![Datum Systems M7 Series Скачать руководство пользователя страница 162](http://html1.mh-extra.com/html/datum-systems/m7-series/m7-series_installation-and-operation-manual_514098162.webp)
Maintenance
M7/M7L/M7LT Modular Satellite Modem
3-106
M7/M7L/M7LT - Rev. 0.05
3.10.3.1.1.
HUB (Site A) Modulator AUPC PtMP Setup
1. Take note of the
<Unit: IP Control Address>
parameter as it will be required later in the
setup of the hub dual demodulators.
2. Set the
<Unit: IP Control M&C Port Number>
parameter to 9101.
3. Set the
<Mod: IF AUPC Mode>
to “Enabled”.
4. Set the
<Intf: MCC Mode>
parameter to “Full Access”.
5. Set the
<Intf: MCC Send Rate Limit>
parameter to
“0.500 kbps” or higher. This rate is
determined by the number of remote sites in the network and the recommended rate is to
have 0.500 kbps per remote site.
6. Set the
<Intf: MCC Send Address>
and
<Intf: MCC Rcv Address>
parameters to “10” for
this example. This address is set per network requirements and all units at the hub must have
a different MCC address.
NOTE: Steps 7
– 10 are settings for enabling and using the optional AUPC Local mode that can
operate independently at the Hub location.
7. Set the
<Demod: IF AUPC Remote Path>
to “Local”.
8. Set the
< Mod: IF - AUPC Eb/No>
to the desired value, e.g. 9.0 dB.
9. Set the
< Mod: IF - AUPC Max Level>
parameter to the desired level. Determine the value
for this parameter by calculating the maximum power that is allowed to prevent the link from
saturation but should be several dB above the nominal operating point for margin, e.g. -10.0
dBm.
10. Set the
< Mod: IF - AUPC Min Level>
parameter to the desired level. Determine the value
for this parameter by calculating the minimum power that is allowed to prevent the link from
dropping below the operating threshold but should be several dB below the nominal operating
point for margin, e.g. -15.0 dBm.
3.10.3.1.2.
HUB (Site A) Dual Demodulator A AUPC PtMP Setup
1. Set the
<Unit: IP Control Address>
parameter to be in the same subnet at the Hub
modulator but not the same address as any other unit connected to the LAN.
2. Set the
<Unit: IP Control M&C Port Number>
parameter to 9101. Port 9101 is the default
port and this can be set per network requirements BUT all units in the AUPC PtMP
configuration MUST be set to the same port number.
3. Set the
<Unit: IP Control M&C Rmt Path>
address parameter to match the Hub Modulator
<Unit: IP Control Address>
parameter.
4. Set the
<Intf: MCC Mode>
parameter to “Full Access”.
5. Set the
<Intf: MCC Rcv 1 Address>
parameters to “11” and
<Intf: MCC Rcv 2 Address>
parameters to “12” for this example. This address is set per network requirements and all
units at the hub must have a different MCC address.
HUB (Site A) Dual Demodulator A; Demod 1 AUPC PtMP Setup
6. Set the
<Demod: IF AUPC Remote Path>
to “Out IP Port”.
7. Set the
<Demod: IF AUPC Remote MCC Address>
to “1” for this example. The setting of
this address can be any address between 1 and 254 but must match the
<Intf: MCC Send
Address>
and <
Intf: MCC Rcv Address>
parameter settings of the modem at the specific
remote site transmitter that is being received by Dual Demodulator A; Demod 1.
HUB (Site A) Dual Demodulator A; Demod 2 AUPC PtMP Setup
8. Set the
<Demod: IF AUPC Remote Path>
to “Out IP Port”.
9. Set the
<Demod: IF AUPC Remote MCC Address>
to “2” for this example. The setting of
this address can be any address between 1 and 254 but must match the
<Intf: MCC Send
Address>
and <
Intf: MCC Rcv Address>
parameter settings of the modem at the specific
remote site transmitter that is being received by Dual Demodulator A; Demod 2.
3.10.3.1.3.
HUB (Site A) Dual Demodulator B AUPC PtMP Setup
1. Set the <Unit: IP Control Address> parameter to be in the same subnet at the Hub modulator
but not the same address as any other unit connected to the LAN.
Содержание M7 Series
Страница 2: ...This page is intentionally blank ...
Страница 10: ......
Страница 56: ......
Страница 66: ...Maintenance M7 M7L M7LT Modular Satellite Modem 3 10 M7 M7L M7LT Rev 0 05 Figure 3 8 Unit Events Log Page ...
Страница 170: ......