I P - D S U U s e r ’ s M a n u a l
02/02/08
14
Plug one end of the V.35 (requires DB25 to V.35 adapter) or RS232-C device cable into
the
IP-DSU
device interface, and the other end into the existing trunk cable or BNS trunk
I/O board.
Plug the power supply into a standard 115V AC outlet and plug the barrel connector
from the power supply into the circular connector on the
IP-DSU
faceplate labeled “5
VDC”.
3.3.2 DC
ONLY
Attach the provided feet to the bottom of the unit.
Fasten the strain-relief bracket to the side of the
IP-DSU
.
Place the
IP-DSU
in the desired location, such as a shelf in a data equipment rack.
Plug one end of the RJ45-terminated category 5 twisted-pair data cable into the
IP-DSU
10BaseT LAN interface, and the other into a 10BaseT LAN hub or router.
Plug one end of the RJ45-terminated twisted-pair data cable into the
IP-DSU
console
interface, and the other into the port of the asynchronous device that will be used to
configure or manage the
IP-DSU
.
Plug one end of the V.35 (requires DB25 to V.35 adapter) or RS232-C device cable into
the
IP-DSU
device interface, and the other end into the existing trunk cable or BNS trunk
I/O board.
Run your 48V DC (return, minus and ground) wires from a central source through the
strain-relief clamp for DC wire stabilization. On the
IP-DSU
faceplate, attach the return,
minus and ground wires to the return, minus and ground connections, respectively, of
the terminal block labeled “48 VDC”.
3.4 Rack-mount
Installation
3.4.1 AC
ONLY
Prepare each
IP-DSU
for rack mounting by attaching the mounting ears to each side of
the unit.
Fasten the twelve-slot rack-mount panel to a 19-inch equipment rack, or use extension
ears for a 23-inch rack. Slide each
IP-DSU
with mounting ears into one of the twelve
rack-mount panel slots. Secure the
IP-DSU
to the rack mount panel with screws.
For each
IP-DSU
, plug one end of the RJ45-terminated category 5 twisted-pair data
cable into the
IP-DSU
10BaseT LAN interface and the other end into a 10BaseT LAN
hub or router.
For each
IP-DSU
, plug one end of the RJ45-terminated twisted-pair data cable into the
IP-DSU
console interface, and the other end into the asynchronous device.
For each
IP-DSU
, plug one end of the V.35 (requires DB25 to V.35 adapter) or RS232-C
device cable into the
IP-DSU
device interface, and the other end into the existing trunk
cable or BNS trunk I/O board.