Device Commands 

Set commands are available to the administrator only 

get location 

This command returns the iBoot-G2’s location ID. 

New Boot 

set location <20 char. max> 

This command is used to set the iBoot-G2’s location ID. 

 

set upgrade enable <yes | no> 

Enables or disables the ability to upload new firmware to 
the iBoot-G2. 

yes 

get upgrade enable 

This command displays the upload enable status. 

 

logout 

Terminates the session 

 

reboot This 

command 

reboots the iBoot-G2. 

 

 

Expansion Commands 

These commands are only available to the administrator. 

get expansion 

This command displays the current settings of the 
expansion ports.  The response to this command is 
determined by the expansion mode setting. 
 
If iBoot-Exp mode: 
 

Link

 

Exp

 

1:

        

Yes

   

Exp

 

2:

        

No

 

 
If Independent I/O mode: 

 

Output

 

Exp1:

   

  

IP

 

Address:

  

192.168.1.202

 

  

Relay:

       

2

 

Exp2:

   

  

IP

 

Address:

  

192.168.1.203

 

  

Relay:

       

3

 

 

 

set expansion mode <exp | io> 

This command sets the mode for the expansion ports to 
either iBoot-Exp or External I/O 

exp 

set expansion <exp1 | exp2> link <yes 
|no> 

This command sets the Exp1 or Exp2 to be linked to the 
main outlet for simultaneous control.  This command 
takes effect only when expansion mode is exp. 

no 

set  expansion <exp1 | exp2> ipaddress 
<dotted decimal> 

This command sets the IP address to send input status 
information via DxP protocol to. This command takes 
effect only when expansion mode is io. 

 

set expansion <exp1 | exp2> relay <1-8> 

This command sets the relay number to be controlled by 
input changes from Exp1 or Exp2.  This command takes 
effect only when expansion mode is io. 

Exp1:  2 
Exp 2: 3 

 

Network Commands 

All set commands require a reboot before they take effect.  These 
commands are only available to the administrator. 

get network 
 

This command will return all the network settings as 
shown below: 

 

Mode:

          

Static

 

IP

 

Address:

    

192.168.1.254

 

Subnet

 

Mask:

   

255.255.255.0

 

Gateway:

       

192.168.1.1

 

HTTP

 

Port:

     

80

 

Telnet

 

Port:

   

23

 

 

Содержание iBoot G2+

Страница 1: ...able The iBoot G2 provides you the ability to reboot crashed devices with the click of a mouse Be sure to read up on all the features of the iBoot G2 Including Web Based setup and control Telnet setup and control Event Scheduling Set power actions on regular intervals Expansion Add low cost iBoot EXP units for up to three outlets controlled AutoPing Automatic monitoring and action for failed equip...

Страница 2: ...2 prong adapter at the receptacle use of this type adapter may result in risk of electrical shock and or damage to this product 9 Do not allow anything to rest on the power cord Do not locate this product where the cord will be abused by persons walking on it 10 Do not overload wall outlets and extension cords as this can result in the risk of fire or electric shock 11 Never push objects of any ki...

Страница 3: ...ings and to save on wear and tear Power up alert devices like sirens lamps messages or control environmental system like heaters coolers pumps etc 3 2 Multiple Control Options In addition to the Web control capabilities iBoot G2 features several other means to operate automatically or under computer control AutoPing The AutoPing feature allows iBoot G2 to automatically detect failed equipment and ...

Страница 4: ...and control additional devices Inputs on the expansion ports can be used to monitor alarm contacts environmental sensors relays and switch closures The outputs can drive relays for process control security and environmental controls iBoot G2 uses Dataprobe Exchange Protocol DxP to communicate with other Dataprobe devices to allow transport of GPIO information across the network DxP protocol is ava...

Страница 5: ...an IEC320 receptacle and detachable power cord an IEC to IEC extension cord can be used The iBoot G2 can be connected to a power strip to allow simultaneous control of multiple devices Make sure that the combined load of all controlled devices does not exceed 12 Amps for 105 125VAC or 10 Amps for 210 240VAC An LED Indicator next to the Switched Outlet will be On to indicate that the power is On at...

Страница 6: ...minals are tightened securely and that there are no loose strands of cable or excessive stripped wires Connecting to iBoot Exp Terminal blocks are connected pin to pin with the iBoot Exp as shown Connect Function iBoot G2 iBoot Exp Power V Power Out V Power In Feedback I Input O Output Ground G Ground G Ground Command O Output I Input Expansion units iBoot Exp are shipped with a cable for easy con...

Страница 7: ...he USB port install the USB driver Download the driver at http dataprobe com support iboot html USB Driver Installation Run ibootG2Driver exe prior to connecting the iBoot G2 to the USB port of the PC Connect the USB iBoot G2 to a USB port of the PC The PC will discover the iBoot G2 and assign a COM port To find the COM port go to Control Panel System Device Manager Ports COM LPT The com port assi...

Страница 8: ...rdware Installing the Wall Mounting Kit DIN Rail Mounting 1 Remove the four mounting screws from the underside of the unit Do not disassemble the unit 1 Install the Wall Mounting Kit as shown 2 Install the wall mounting ears to the unit using the screws removed in Step 2 2 Install the DIN rail clips using the four screws provided 3 The unit is ready for wall mounting 3 Ready for DIN rail mounting ...

Страница 9: ...CP server on your network If the IP address was assigned by a DHCP server no changes to the IP Address are required The IP address field also indicates the port for web access that is used by the iBoot The standard port for web browser control is factory default Port 80 Change the IP Address 1 Click on the row containing the iBoot G2 to be set The row will become highlighted 2 From the menu select...

Страница 10: ... what address is assigned to the iBoot You can lock the iBoot G2 to the current address by selecting IP Mode Static without changing the addresses Set the IP Mode either by using the web setup page or via Telnet commands If you set the IP address using another method the address becomes static To return iBoot G2 to dynamic addressing using DHCP select DHCP mode in Network Setup and reboot the unit...

Страница 11: ...t by leaving the user logged in As the iBoot G2 allows only one Web user logged in at any time use caution when disabling the timeout feature as it is possible to lock out other users by forgetting to logout Closing the browser will not log the user out and will lock out web access If you do become locked out access the iBoot G2 via Telnet and reboot the unit or press the reset button see Section ...

Страница 12: ... connecting with the Admin credentials reset buttons for the Trigger counters are provided Heartbeat Enabled If the Heartbeat feature is enabled the page will display the current status OK or Fail of the Heartbeat with a counter showing how many times the Action was triggered If connecting with the Admin credentials reset buttons for the Trigger counters are provided Navigation Buttons Refresh Use...

Страница 13: ...eb user logged in at any time use caution when disabling the timeout feature as it is possible to lock out other users by forgetting to logout Closing the browser will not log the user out and will lock out web access If you do become locked out access the iBoot G2 via Telnet and reboot the unit or press the reset button 7 2 Expansion Settings Mode Set iBoot Exp or Independent I O mode iBoot Exp d...

Страница 14: ... is 9105 then use the address http 192 168 1 254 9105 Telnet Port This setting is used to allow access to the iBoot G2 via telnet by ports other than standard 23 DxP Port This setting is used to allow access to the iBoot G2 via Dataprobe Exchange Protocol DxP via ports other than standard 9100 Enable DxP Control This setting enables external devices to control the iBoot G2 via DxP protocol Enable ...

Страница 15: ...work device and powers up alarm or redundant system when there is no response Ideal for Hot Standby Servers Environmental Control Alert for any Network Failure iBoot G2 supports three independent AutoPing channels each controlling either the Main power or either of the two Expansion ports The first AutoPing channel can be programmed with two separate IP Addresses with logical AND OR comparisons to...

Страница 16: ... device Power Cycle Once Upon triggering iBoot G2 will cycle power one time It will not cycle again automatically until the ping response returns and is lost again With AutoPing operational the main iBoot G2 page will display the current status of this feature The status will be OK to indicate that iBoot G2 is receiving responses to the ping or that the fail counter has not yet been exceeded If th...

Страница 17: ...run as a tray applet that will transmit heartbeats at a steady interval to an iBoot A Windows dll file is also available for use by Windows applications The Heartbeat Protocol will allow developers to imbed this capability directly into their software products 7 7 Heartbeat Settings Source Select the source of the heartbeat either USB Network or None heartbeat not used When using the Network enter...

Страница 18: ...eartbeat is turned off Make sure your Heartbeat frequency is longer than the time required to reboot your device Power Cycle Once Upon triggering iBoot G2 will cycle power one time It will not cycle again automatically until the heartbeat returns and is lost again Outlet Select Main for the internal power outlet or Exp1 Exp 2 for either of the two expansion ports 7 8 Using Heartbeat Monitor With H...

Страница 19: ...urs or Minutes Action Set the event Action On Off or Cycle Click Save to save the current settings Click Clear to delete any current schedule Note All of the Schedule Settings require a reboot of the iBoot G2 after clicking Save A Reboot button will appear at the bottom of the page The new settings will not take effect until the unit is rebooted Reboot will not affect the power position of the iBo...

Страница 20: ...it No Flow Control Once the connection is made send Enter When connection is successful the User prompt is displayed Enter user or admin and press Enter The prompt will change to Password Enter the admin or user password and press Enter The prompt will change to iBoot This indicates successful login Enter commands as needed When done enter the logout command 8 2 iBoot G2 CLI Syntax Command Descrip...

Страница 21: ...ess 192 168 1 203 Relay 3 set expansion mode exp io This command sets the mode for the expansion ports to either iBoot Exp or External I O exp set expansion exp1 exp2 link yes no This command sets the Exp1 or Exp2 to be linked to the main outlet for simultaneous control This command takes effect only when expansion mode is exp no set expansion exp1 exp2 ipaddress dotted decimal This command sets t...

Страница 22: ...ich is TCP 9100 set dxp port 0 65535 This command sets the port that the iBoot G2 s DxP protocol service listens for incoming connections on When set to 0 the Protocol service is disabled Note At least one of the above MUST NOT be 0 The CLI will protect against all 3 from being set to 0 9100 set dxp control enable disable This command allows the main and expansion ports to be controlled using Data...

Страница 23: ...gs Source USB Status Trigger Count Frequency 10 OK 0 Fail Count 3 Action Cycle Once Outlet Main set heartbeat source none usb network This command sets the source for the heartbeat Either USB or Network None set heartbeat frequency 1 999 This command is used to set the frequency in seconds How often the iBoot G2 expects the heartbeat 10 set heartbeat failcount 1 999 This command is used to set the...

Страница 24: ...led action s start date set event 1 8 time hh mm This command is used to set the time the scheduled action will occur in 24 hour format set event 1 8 repeat minute hour day This command is used to set the increments for repeating scheduled actions set event 1 8 mult 0 999 This command sets how often the event will repeat the number of increments as set by the command above before the next event se...

Страница 25: ...the release notes for the upgrade before making changes to you iBoot G2 1 Insure that the Upgrade Enable checkbox is checked in the Network Setup web page of the iBoot G2 2 Run the Device Management Utility available at the link above If the iBoot G2 you would like to upgrade is not visible in the list box either Select Device Discover from the menu to locate iBoot G2 units on the local network or...

Страница 26: ... expected Use the pushbutton as follows Action Result Momentary Soft Reset Will not change outlet status 5 Seconds push Reset to Factory Defaults Hold the button in until the Outlet LED is blinking then release Hold in while and Power up the iBoot Recovery Mode Allows upload of new firmware to Factory default IP Address 192 168 1 254 ...

Страница 27: ...12 VDC power out from the iBoot G2 Maximum current 100 mA Feedback I Input Input for status signals Dry Contact input or Open Collector Ground G Ground Signal Ground for Input and Output Command O Output 2N3904 NPN Transistor 100 mA Maximum 12 4 Compliance UL cUL UL60950 Listed I T E File No E225914 CE Directives 89 336 EEC 92 31 EEC and 93 68 EEC EN 60950 3rd Edition EN 55022 1998 Class B FCC Par...

Страница 28: ...e at 201 934 5111 to receive a Return Materials Authorization RMA Number prior to sending any equipment back for repair Include all cables power supplies and proof of purchase with shipment THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT MISUSE ABUSE OR NEGLECT SELLER MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY EXPRESSLY SET FORTH HEREIN EXCEPT TO THE EXTEN...

Отзывы: