19-PIN CONNECTOR ELECTRICAL CONNECTIONS
79
5
INPUT 2 CONNECTIONS USING EXTERNAL POWER
Matrix 400™
INPUT DEVICE
Vext 30 Vdc max.
D
E
V
CC
~
~
+
-
V
Signal
I2A
I2B
I
in
Figure 95 - Input PNP Using External Power
Matrix 400™
INPUT DEVICE
Vext 30 Vdc max.
D
E
Signal
V
V
CC
~
~
+
-
I2A
I2B
Figure 96 - Input NPN Using External Power
5.9 OUTPUTS
Two opto-coupled general purpose outputs are available on the M16 19-pin connector. The
meaning of the two outputs Output 1 and Output 2 can be defined by the user. They are
typically used either to signal the data collection result or to control an external lighting
system.
The pinout is the following:
Pin Name Function
H
O1+
Configurable digital output 1 - positive pin
F
O1-
Configurable digital output 1 - negative pin
G
O2+
Configurable digital output 2 - positive pin
I
O2-
Configurable digital output 2 - negative pin
The electrical features of the two outputs are the following:
OUTPUT I
Load
V
Out
Open
0 mA
30 Vdc Max
Closed
10 mA
1.8 Vdc Max
P
D
= V
Out
I
oLoad
= 170 mW Max.
By default, Output 1 is associated with the Partial Read and No Read events, which activates
when the code(s) signaled by the external trigger are not decoded, and Output 2 is
associated with the Complete Read event, which activates when all the selected codes are
correctly decoded.
Содержание Matrix 400
Страница 1: ...MATRIX 400 Reference Manual...
Страница 59: ...CBX ELECTRICAL CONNECTIONS 49 4 Figure 55 Matrix 400 Multidrop Connection to a Multiplexer...
Страница 62: ...MATRIX 400 REFERENCE MANUAL 52 4 Figure 57 ID NET Network Connections with isolated power blocks...
Страница 63: ...CBX ELECTRICAL CONNECTIONS 53 4 Figure 58 ID NET Network Connections with Common Power Branch Network...
Страница 64: ...MATRIX 400 REFERENCE MANUAL 54 4 Figure 59 ID NET Network Connections with Common Power Star Network...
Страница 81: ...19 PIN CONNECTOR ELECTRICAL CONNECTIONS 71 5 Figure 83 ID NET Network Connections with isolated power blocks...
Страница 82: ...MATRIX 400 REFERENCE MANUAL 72 5 Figure 84 ID NET Network Connections with Common Power Branch Network...
Страница 115: ...SOFTWARE CONFIGURATION 105 8 Figure 116 Options Communication Serial Port Figure 117 Options Communication Ethernet...
Страница 142: ...www automation datalogic com...