![Datalogic Matrix 400 Скачать руководство пользователя страница 104](http://html1.mh-extra.com/html/datalogic/matrix-400/matrix-400_reference-manual_3685101104.webp)
MATRIX 400™ REFERENCE MANUAL
94
7
Example:
The FOV for a
Matrix 400 600-0x0 base
using the
16 mm lens
at a
focus distance of 200
mm
is:
FOV
H
= 2 [(200 mm + 35 mm) tan (24°/2)] =
100 mm
FOV
V
= 2 [(200 mm + 35 mm) tan (18°/2)] =
74 mm
7.2 HORIZONTAL FOV VS. READING DISTANCE DIAGRAMS
The following graphs represent the Horizontal Field of View (FOV) and Reading Distance
based on the combination of a certain sensor (Matrix 400™ base model) and a certain lens.
Each point represents the maximum achievable Field of View with the selected code
resolution (in this point DOF is limited).
NOTE
The following diagrams are given for typical performance at 25°C using
high quality grade A symbols according to ISO/IEC 15416 (1D code) and
ISO/IEC 15415 (2D code) print quality test specifications. Testing should
be performed with actual application codes in order to maximize the
application performance.
7.2.1 How to Use the Diagrams
0
5
10
15
20
25
30
35
40
0
10
20
30
40
50
60
70
80
90
100 110 120 130 140 150 160 170 180 190 200 210 220 230
Reading Distance (cm)
Hor
izontal FOV (cm)
SXGA - 25 mm
SXGA - 35 mm
SXGA - 50 mm
0.25
0.20
0.20
0.25
0.30
0.33
0.38
0.25
0.50
0.30
0.33
0.38
0.38
0.50
0.50
0.33
0.30
0.15
0.10
0.15
0.10
0.20
0.15
For a given code resolution,
the blue line represents the
maximum Horizontal FOV.
The reading distance can be
selected by changing the lens.
For a given Reading Distance you must
select the lens that is able to read your
code resolution.
Each point represents the maximum FOV for a given
code resolution.
You can read this resolution code with the same
lens at shorter distances but sacrificing FOV.
Содержание Matrix 400
Страница 1: ...MATRIX 400 Reference Manual...
Страница 59: ...CBX ELECTRICAL CONNECTIONS 49 4 Figure 55 Matrix 400 Multidrop Connection to a Multiplexer...
Страница 62: ...MATRIX 400 REFERENCE MANUAL 52 4 Figure 57 ID NET Network Connections with isolated power blocks...
Страница 63: ...CBX ELECTRICAL CONNECTIONS 53 4 Figure 58 ID NET Network Connections with Common Power Branch Network...
Страница 64: ...MATRIX 400 REFERENCE MANUAL 54 4 Figure 59 ID NET Network Connections with Common Power Star Network...
Страница 81: ...19 PIN CONNECTOR ELECTRICAL CONNECTIONS 71 5 Figure 83 ID NET Network Connections with isolated power blocks...
Страница 82: ...MATRIX 400 REFERENCE MANUAL 72 5 Figure 84 ID NET Network Connections with Common Power Branch Network...
Страница 115: ...SOFTWARE CONFIGURATION 105 8 Figure 116 Options Communication Serial Port Figure 117 Options Communication Ethernet...
Страница 142: ...www automation datalogic com...