![Datalogic Matrix 400 Скачать руководство пользователя страница 73](http://html1.mh-extra.com/html/datalogic/matrix-400/matrix-400_reference-manual_3685101073.webp)
19-PIN CONNECTOR ELECTRICAL CONNECTIONS
63
5
5 MATRIX 400™ CONNECTOR ELECTRICAL CONNECTIONS
5.1 M16 19-PIN CONNECTOR
The Matrix 400™ reader is equipped with an M16 19-pin male connector (Binder, 423
Series) for connection to the power supply, serial interfaces and input/output signals. The
details of the connector pins are indicated in the following table:
Figure 73 – M16 19-pin Male Connector
19-pin M16 male connector pinout
Pin Name
Function
A
Vdc
Power supply input v
L
GND
Power supply input voltage -
K CHASSIS
Cable shield internally connected by capacitor to the
chassis
B
I1A
External Trigger A (polarity insensitive)
C
I1B
External Trigger B (polarity insensitive)
D
I2A
Input 2 A (polarity insensitive)
E
I2B
Input 2 B (polarity insensitive)
H
O1+
Output 1 +
F
O1-
Output 1 -
G
O2+
Output 2 +
I
O2-
Output 2 -
S
RX
Auxiliary RS232 RX
O
TX
Auxiliary RS232 TX
R ID+
ID-NET™
network
+
P ID-
ID-NET™
network
-
Pin Name RS232
RS485
Full-Duplex
RS485
Half-Duplex
M TX
TX+
RTX+
U RX
*
RX+
N RTS
TX-
RTX-
T
MAIN
INTERFACE
(SW
SELECTABLE)
CTS
*
RX-
* Do not leave floating, see par. 5.4.2 for connection details.
In order to meet EMC requirements:
connect the reader chassis to the plant earth ground by means of a flat copper braid
shorter than 100 mm;
connect the main interface cable shield to pin K of the 19-pin connector;
Содержание Matrix 400
Страница 1: ...MATRIX 400 Reference Manual...
Страница 59: ...CBX ELECTRICAL CONNECTIONS 49 4 Figure 55 Matrix 400 Multidrop Connection to a Multiplexer...
Страница 62: ...MATRIX 400 REFERENCE MANUAL 52 4 Figure 57 ID NET Network Connections with isolated power blocks...
Страница 63: ...CBX ELECTRICAL CONNECTIONS 53 4 Figure 58 ID NET Network Connections with Common Power Branch Network...
Страница 64: ...MATRIX 400 REFERENCE MANUAL 54 4 Figure 59 ID NET Network Connections with Common Power Star Network...
Страница 81: ...19 PIN CONNECTOR ELECTRICAL CONNECTIONS 71 5 Figure 83 ID NET Network Connections with isolated power blocks...
Страница 82: ...MATRIX 400 REFERENCE MANUAL 72 5 Figure 84 ID NET Network Connections with Common Power Branch Network...
Страница 115: ...SOFTWARE CONFIGURATION 105 8 Figure 116 Options Communication Serial Port Figure 117 Options Communication Ethernet...
Страница 142: ...www automation datalogic com...