RAPID CONFIGURATION
13
1
2. Remove the lens cover in order to focus the reader and loosen the two Locking Knobs on
the lens.
Adjust the Focus ring to the "
Far position
" and the Diaphragm ring to the "
F4
"
number
setting which is the preferred setting for installation.
Place the
Grade A Barcode Test Chart
in front of the reader at the correct reading
distance (see step 3 and the Optical Accessory Selection table in the par. 7.1).
3. Press the "Positioning" button. The reader continuously acquires images and gives visual
feedback in the view image window. Select the largest code from the chart that
completely fits into the view image window. Move the reader (or code) to center it. The
code must be aligned across the X-axis reference line at the center of the FOV. See
figure below.
Press the Positioning button again to stop positioning.
2
For far reading distances, the Diaphragm ring can be set to values between
F2
and
F4
to increase image lighting.
3
Содержание Matrix 400
Страница 1: ...MATRIX 400 Reference Manual...
Страница 59: ...CBX ELECTRICAL CONNECTIONS 49 4 Figure 55 Matrix 400 Multidrop Connection to a Multiplexer...
Страница 62: ...MATRIX 400 REFERENCE MANUAL 52 4 Figure 57 ID NET Network Connections with isolated power blocks...
Страница 63: ...CBX ELECTRICAL CONNECTIONS 53 4 Figure 58 ID NET Network Connections with Common Power Branch Network...
Страница 64: ...MATRIX 400 REFERENCE MANUAL 54 4 Figure 59 ID NET Network Connections with Common Power Star Network...
Страница 81: ...19 PIN CONNECTOR ELECTRICAL CONNECTIONS 71 5 Figure 83 ID NET Network Connections with isolated power blocks...
Страница 82: ...MATRIX 400 REFERENCE MANUAL 72 5 Figure 84 ID NET Network Connections with Common Power Branch Network...
Страница 115: ...SOFTWARE CONFIGURATION 105 8 Figure 116 Options Communication Serial Port Figure 117 Options Communication Ethernet...
Страница 142: ...www automation datalogic com...