READING FEATURES
93
7
7 READING FEATURES
7.1 OPTICAL ACCESSORY SELECTION
Referring to Figure 112 and the formula below, use the data in the following table to calculate
the FOV for your application.
Model Lens
Viewing Angle
Horizontal
Viewing Angle
Vertical
Viewing Angle
Diagonal
Min Focus Distance
mm
LNS-1109 9 mm
48.5°
39.5°
60°
85
LNS-1112 12.5 mm
37°
30°
46.5°
85
LNS-1116 16 mm
28.5°
23°
36°
85
LNS-1125 25 mm
18.5°
15°
23.5°
135
LNS-1135 35 mm
13°
10,5°
16.5°
235
Matrix 400
400-0x0
(SXGA)
LNS-1150 50 mm
9°
7°
11.5°
500
LNS-1006 6 mm
59.5°
46.5°
71°
85
LNS-1109 9 mm
40.5°
31°
49.5°
85
LNS-1112 12.5 mm
31°
23.5°
38°
85
LNS-1116 16 mm
24°
18°
30°
85
LNS-1125 25 mm
15°
11.5°
19°
135
LNS-1135 35 mm
11°
8.5°
13.5°
235
Matrix 400
600-0x0
(UXGA)
LNS-1150 50 mm
7.5°
5.5°
9.5°
500
The viewing angle has a tolerance of
1° depending on the focus distance.
FOV
x
= 2 (d + 35 mm) tan (
x
/2)
where:
FOV
x
= horizontal, vertical or diagonal FOV
x
= horizontal, vertical or diagonal viewing angles.
d
= focus distance
d
35 mm
FOV
plane
Figure 112 – Reading Distance References
Содержание Matrix 400
Страница 1: ...MATRIX 400 Reference Manual...
Страница 59: ...CBX ELECTRICAL CONNECTIONS 49 4 Figure 55 Matrix 400 Multidrop Connection to a Multiplexer...
Страница 62: ...MATRIX 400 REFERENCE MANUAL 52 4 Figure 57 ID NET Network Connections with isolated power blocks...
Страница 63: ...CBX ELECTRICAL CONNECTIONS 53 4 Figure 58 ID NET Network Connections with Common Power Branch Network...
Страница 64: ...MATRIX 400 REFERENCE MANUAL 54 4 Figure 59 ID NET Network Connections with Common Power Star Network...
Страница 81: ...19 PIN CONNECTOR ELECTRICAL CONNECTIONS 71 5 Figure 83 ID NET Network Connections with isolated power blocks...
Страница 82: ...MATRIX 400 REFERENCE MANUAL 72 5 Figure 84 ID NET Network Connections with Common Power Branch Network...
Страница 115: ...SOFTWARE CONFIGURATION 105 8 Figure 116 Options Communication Serial Port Figure 117 Options Communication Ethernet...
Страница 142: ...www automation datalogic com...