AMT58x-PN ProfiNET®
61
Scaling function control
This parameter enables / disables the Scaling function. When this
parameter is disabled, the device uses the hardware singleturn and
multiturn resolutions; when it is enabled, the device uses the
resolutions set next to the parameters
Measuring units / Revolution
and
Total measuring range.
Refer also to the section “Scaling
function parameters”on page 67.
Attribute
Meaning
Value
Disable
Scaling function disabled
0
Enable
Scaling function enabled
1
NOTE
There is no functionality of this parameter if the
Class 4
functionality
parameter is disabled.
Alarm channel control
This parameter enables / disables the encoder specific Alarm
channel transferred as Channel Related Diagnosis. This functionality
is used to limit the amount of data sent in isochronous mode.
If the value is zero (0 = default value), only the communication
related alarms are sent via the alarm channel. If the value is one (1),
also the encoder specific faults and warnings are sent via the alarm
channel.
For further information refer also to the section “10.2 Error messages
via the Alarm Channel”.
Attribute
Meaning
Value
Disable
No profile specific diagnosis
0
Enable
Profile specific diagnosis
1
NOTE
This parameter is only supported in compatibility mode (see
Compatibility mode
on page 67).
Содержание AMT58*-PN Series
Страница 1: ......
Страница 16: ......
Страница 21: ...AMT58x PN ProfiNET 5 3 1 3 Installation using a flange code ST 58 FLNG ...
Страница 30: ...AMT58x PN ProfiNET 14 Figure 5 Scrolling through Profinet families and categories ...
Страница 114: ...AMT58x PN ProfiNET 98 13 Read write records in acyclic communication Figure 58 Base mode parameter request and response ...
Страница 116: ...AMT58x PN ProfiNET 100 13 1 3 Data Block 1 DB1 Figure 61 DB1 13 1 4 Data Block 2 DB2 Figure 62 DB2 ...
Страница 117: ...AMT58x PN ProfiNET 101 13 1 5 Data Block 3 DB3 Figure 63 DB3 13 1 6 Data Block 4 DB4 Figure 64 DB4 ...
Страница 118: ...AMT58x PN ProfiNET 102 13 1 7 Organization Block 1 OB1 Figure 65 OB1 13 1 8 Function 1 FC1 Figure 66 FC1 ...
Страница 119: ...AMT58x PN ProfiNET 103 Figure 67 FC1 13 1 9 Function 2 FC2 Figure 68 FC2 ...
Страница 123: ...AMT58x PN ProfiNET 107 14 1 Normal operation diagram ...
Страница 124: ...AMT58x PN ProfiNET 108 14 2 Preset diagram ...
Страница 125: ...AMT58x PN ProfiNET 109 14 3 Parking sensor diagram ...
Страница 126: ...AMT58x PN ProfiNET 110 14 4 Error diagram 14 4 1 Acknowledgment of acknowledgeable sensor error ...
Страница 127: ...AMT58x PN ProfiNET 111 14 4 2 Acknowledgment of not acknowledgeable sensor error ...
Страница 145: ......