IRT
Synchronized transmission procedure for the cyclic exchange of IRT data
between PROFINET devices. A reserved bandwidth within the send clock
is available for the IRT IO data. The reserved bandwidth ensures that the
IRT data can be transmitted at reserved, synchronized intervals whilst
remaining uninfluenced even by other greater network loads (e.g. TCP/IP
communication or additional real time communication). The "high
flexibility" enables simple planning and expansion of the system. A
topological configuration is not required. Refer to page 77.
MAC address The MAC address is an identifier unique wordlwide consisting of two
parts: the first 3 bytes are the manufacturer ID and are provided by IEE
standard autority; the last three bytes represent a consecutive number of
the manufacturer. Refer to page 8.
Module
Modules are user defined components that plug into slots. Modules can
be real or virtual.
NRT
Non Real Time - The non Real Time PROFINET IO Channel.
Configuration and diagnostic messages are transferred over the NRT
Channel.
Organization
block
A range of organization blocks (OB) are designed to execute the user
program. OBs are the interface interface between the user program and
the operating system of a CPU. They permit event-controlled processing
of special program components within the user program.The order in
which the user program is executed is defined in the organization blocks.
Profile
Profiles define application-specific functionality to ensure the openness of
PROFIBUS and PROFINET is utilized consistently. PI Profiles can cover
simple devices such as encoders by defining how signals are used and
how they are physically connected. However, profiles are increasingly
covered more complex systems or requirements. Profiles such as
PROFIdrive and PROFIsafe deliver active functionality as well. An
advanced profile covering active power management for end devices like
lasers and robots is now under development with the aim of bringing
significant reductions in energy consumption for the automotive industry.
Profiles guarantee quicker system design and they support faster device
interchange, promoting competition amongst vendors, increased choice
for users and full interoperability.
Provider
Status
The Status an IO device provides to an IO Controller with the data
transferred to the Controller.
Proxy
A device which maps non PROFINET IO data to PROFInet.
Real-time Real-time
means
that a system processes external events within a
defined time. If the reaction of a system is predictable, one speaks of a
deterministic system. The general requirements for real-time are
therefore: deterministic response and defined response time. Refer to
page 77.
RT
Real Time - The Real Time PROFINET IO Channel. I/O and Alarm Data
are transferred over the RT Channel. Refer to page 77.
Slot
A group of one or more Subslots. Slots can be real or virtual.
Standard
signal
The encoder profile defines a series of standard signals which are used to
configure the IO data. Refer to page 46.
Содержание AMT58*-PN Series
Страница 1: ......
Страница 16: ......
Страница 21: ...AMT58x PN ProfiNET 5 3 1 3 Installation using a flange code ST 58 FLNG ...
Страница 30: ...AMT58x PN ProfiNET 14 Figure 5 Scrolling through Profinet families and categories ...
Страница 114: ...AMT58x PN ProfiNET 98 13 Read write records in acyclic communication Figure 58 Base mode parameter request and response ...
Страница 116: ...AMT58x PN ProfiNET 100 13 1 3 Data Block 1 DB1 Figure 61 DB1 13 1 4 Data Block 2 DB2 Figure 62 DB2 ...
Страница 117: ...AMT58x PN ProfiNET 101 13 1 5 Data Block 3 DB3 Figure 63 DB3 13 1 6 Data Block 4 DB4 Figure 64 DB4 ...
Страница 118: ...AMT58x PN ProfiNET 102 13 1 7 Organization Block 1 OB1 Figure 65 OB1 13 1 8 Function 1 FC1 Figure 66 FC1 ...
Страница 119: ...AMT58x PN ProfiNET 103 Figure 67 FC1 13 1 9 Function 2 FC2 Figure 68 FC2 ...
Страница 123: ...AMT58x PN ProfiNET 107 14 1 Normal operation diagram ...
Страница 124: ...AMT58x PN ProfiNET 108 14 2 Preset diagram ...
Страница 125: ...AMT58x PN ProfiNET 109 14 3 Parking sensor diagram ...
Страница 126: ...AMT58x PN ProfiNET 110 14 4 Error diagram 14 4 1 Acknowledgment of acknowledgeable sensor error ...
Страница 127: ...AMT58x PN ProfiNET 111 14 4 2 Acknowledgment of not acknowledgeable sensor error ...
Страница 145: ......