AMT58x-PN ProfiNET®
8
4.2 P1 Port 1 and P2 Port 2 connectors (Fig.1)
Two M12 4-pin female connectors with D coding are used for
Ethernet connection through port 1 and port 2.
Description
Pin
Tx Data +
1
Rx Data +
2
Tx Data -
3
Rx Data -
4
4.3 Ground connection (Fig.1)
To minimize noise connect properly the shield and/or the connector
housing and/or the frame to ground. Connect properly the cable
shield to ground on user's side. Datalogic's EC- pre-assembled
cables are fitted with shield connection to the connector ring nut in
order to allow grounding through the body of the device. Datalogic's
E- connectors have a plastic gland, thus grounding is not possible. If
metal connectors are used, connect the cable shield properly as
recommended by the manufacturer. Anyway make sure that ground
is not affected by noise. It is recommended to provide the ground
connection as close as possible to the device. We suggest using the
ground point provided in the cap (see Figure 1, use 1 TCEI M3 x 6
cylindrical head screw with 2 tooth lock washers).
4.4 MAC address and IP address
The unit can be identified in the network through the MAC address
and the IP address. MAC address has to be intended as a
permanent and globally unique identifier assigned to the unit for
communication on the physical layer; while the IP address is the
name of the unit in a network using the Internet protocol. MAC
address is 6-byte long and cannot be modified. It consists of two
parts, numbers are expressed in hexadecimal notation: the first three
bytes are used to identify the manufacturer (OUI, namely
Organizationally Unique Identifier), while the last three bytes are the
specific identifier of the unit. The MAC address can be found on the
label applied to the encoder. The IP address (and the subnet mask)
must be assigned by the user to each interface of the unit to be
connected in the network. For additional information on the MAC
address refer to the section “5.2 Mac address” on page 10.
For additional information on the IP address refer to the section
“5.3.7 Setting the IP address” on page 27.
Содержание AMT58*-PN Series
Страница 1: ......
Страница 16: ......
Страница 21: ...AMT58x PN ProfiNET 5 3 1 3 Installation using a flange code ST 58 FLNG ...
Страница 30: ...AMT58x PN ProfiNET 14 Figure 5 Scrolling through Profinet families and categories ...
Страница 114: ...AMT58x PN ProfiNET 98 13 Read write records in acyclic communication Figure 58 Base mode parameter request and response ...
Страница 116: ...AMT58x PN ProfiNET 100 13 1 3 Data Block 1 DB1 Figure 61 DB1 13 1 4 Data Block 2 DB2 Figure 62 DB2 ...
Страница 117: ...AMT58x PN ProfiNET 101 13 1 5 Data Block 3 DB3 Figure 63 DB3 13 1 6 Data Block 4 DB4 Figure 64 DB4 ...
Страница 118: ...AMT58x PN ProfiNET 102 13 1 7 Organization Block 1 OB1 Figure 65 OB1 13 1 8 Function 1 FC1 Figure 66 FC1 ...
Страница 119: ...AMT58x PN ProfiNET 103 Figure 67 FC1 13 1 9 Function 2 FC2 Figure 68 FC2 ...
Страница 123: ...AMT58x PN ProfiNET 107 14 1 Normal operation diagram ...
Страница 124: ...AMT58x PN ProfiNET 108 14 2 Preset diagram ...
Страница 125: ...AMT58x PN ProfiNET 109 14 3 Parking sensor diagram ...
Страница 126: ...AMT58x PN ProfiNET 110 14 4 Error diagram 14 4 1 Acknowledgment of acknowledgeable sensor error ...
Страница 127: ...AMT58x PN ProfiNET 111 14 4 2 Acknowledgment of not acknowledgeable sensor error ...
Страница 145: ......