AMT58x-PN ProfiNET®
63
Measuring units / Revolution
It is used to program a user specific resolution per each revolution
(singleturn resolution). Allowed values are equal to or lower than the
hardware counts per revolution (physical singleturn resolution). We
suggest setting values that are a power of 2 (1, 2, 4, … 2048, 4096,
…). See the parameter
Scaling function control
below.
Default = hardware counts per revolution (min. = 1, max. = hardware
counts per revolution)
NOTE
There is no functionality of this parameter if the
Scaling function
control
parameter is disabled.
EXAMPLE
The HS58 PT Profinet singleturn encoder has a singleturn resolution
of 18 bits (262144 cpr); the permissible value for the
Measuring
units / Revolution
will be between 2
0
and 2
18
(2
18
= 262144).
NOTE
When you change the value next to this parameter, then you are
required to enter a new preset.
Total measuring range
This parameter sets the number of distinguishable steps over the
total measuring range. Allowed values are equal to or lower than the
total hardware resolution value (physical multiturn resolution).
We recommend the Number of revolutions to be set to a power of 2.
The set Number of revolutions results from the following calculation:
Number of revolutions =
Total measuring range
Measuring units /
Revolution
Setting the
Number of revolutions
to a value which is a power of 2
is meant to avoid problems when using the device in endless
operations requiring the physical zero to be overstepped. If you set
the
Number of revolutions
which is not a power of 2, a so-called
"Red Zone" is generated before the physical zero.
For more detailed information refer to the section 9.5 "Red Zone" on
page 71).
Default = total hardware resolution (min. = 2, max. = total hardware
resolution)
NOTE
Содержание AMT58*-PN Series
Страница 1: ......
Страница 16: ......
Страница 21: ...AMT58x PN ProfiNET 5 3 1 3 Installation using a flange code ST 58 FLNG ...
Страница 30: ...AMT58x PN ProfiNET 14 Figure 5 Scrolling through Profinet families and categories ...
Страница 114: ...AMT58x PN ProfiNET 98 13 Read write records in acyclic communication Figure 58 Base mode parameter request and response ...
Страница 116: ...AMT58x PN ProfiNET 100 13 1 3 Data Block 1 DB1 Figure 61 DB1 13 1 4 Data Block 2 DB2 Figure 62 DB2 ...
Страница 117: ...AMT58x PN ProfiNET 101 13 1 5 Data Block 3 DB3 Figure 63 DB3 13 1 6 Data Block 4 DB4 Figure 64 DB4 ...
Страница 118: ...AMT58x PN ProfiNET 102 13 1 7 Organization Block 1 OB1 Figure 65 OB1 13 1 8 Function 1 FC1 Figure 66 FC1 ...
Страница 119: ...AMT58x PN ProfiNET 103 Figure 67 FC1 13 1 9 Function 2 FC2 Figure 68 FC2 ...
Страница 123: ...AMT58x PN ProfiNET 107 14 1 Normal operation diagram ...
Страница 124: ...AMT58x PN ProfiNET 108 14 2 Preset diagram ...
Страница 125: ...AMT58x PN ProfiNET 109 14 3 Parking sensor diagram ...
Страница 126: ...AMT58x PN ProfiNET 110 14 4 Error diagram 14 4 1 Acknowledgment of acknowledgeable sensor error ...
Страница 127: ...AMT58x PN ProfiNET 111 14 4 2 Acknowledgment of not acknowledgeable sensor error ...
Страница 145: ......