AMT58x-PN ProfiNET®
47
G1_XIST3
[Unsigned, 64 bits]
It is defined as Sensor 1 position actual value 3. This 64-bit position
value is intended to support the encoders having a measuring length
which exceeds 32 bits
G1_XIST3
has the following format:
binary
format;
the actual position value is always right aligned, a shifting
factor is not used;
the settings in the encoder parameter data affect the position
value in
G1_XIST3
if Application Class 4 is enabled.
IO
data 1 2 3 4
Format
64-bit position value
STW2_ENC
[Unsigned, 16 bits]
It is defined as Encoder control word 2. Control word
STW2_ENC
includes the
Control by PLC
mechanisms from PROFIdrive STW1
and the
Controller Sign-Of-Life
mechanism from PROFIdrive
STW2. mechanism from PROFIdrive STW2.
Bit
Meaning
0 … 6
Reserved
7 Not
used
8 … 9
Reserved
10
Control by PC
11 Reserved
12 … 15
Controller Sign-Of.Life
Control by PLC
Bit 10
If the
Compatibility mode
is enabled (see on page 90), then bit 10
Control by PLC
is ignored. In this case control word
G1_STW
and
setpoint are always checked.
If the
Compatibility mode
is disabled (see on page 90), then bit 10
Control by PLC
is checked. So control word
G1_STW
and setpoint
are checked only if the bit
Control by PLC
is set.
Bit
Value Significance Comment
10
1
Control from
PLC
Control via interface, EO IO Data is
processed.
0
No control
from PLC
EO IO Data not valid, except Sign-Of-
Life.
Controller Sign-Of-Life
Bits 12 … 15
For more information on the control word
STW2_ENC
please refer to
the PROFIdrive Technical Specification document.
Содержание AMT58*-PN Series
Страница 1: ......
Страница 16: ......
Страница 21: ...AMT58x PN ProfiNET 5 3 1 3 Installation using a flange code ST 58 FLNG ...
Страница 30: ...AMT58x PN ProfiNET 14 Figure 5 Scrolling through Profinet families and categories ...
Страница 114: ...AMT58x PN ProfiNET 98 13 Read write records in acyclic communication Figure 58 Base mode parameter request and response ...
Страница 116: ...AMT58x PN ProfiNET 100 13 1 3 Data Block 1 DB1 Figure 61 DB1 13 1 4 Data Block 2 DB2 Figure 62 DB2 ...
Страница 117: ...AMT58x PN ProfiNET 101 13 1 5 Data Block 3 DB3 Figure 63 DB3 13 1 6 Data Block 4 DB4 Figure 64 DB4 ...
Страница 118: ...AMT58x PN ProfiNET 102 13 1 7 Organization Block 1 OB1 Figure 65 OB1 13 1 8 Function 1 FC1 Figure 66 FC1 ...
Страница 119: ...AMT58x PN ProfiNET 103 Figure 67 FC1 13 1 9 Function 2 FC2 Figure 68 FC2 ...
Страница 123: ...AMT58x PN ProfiNET 107 14 1 Normal operation diagram ...
Страница 124: ...AMT58x PN ProfiNET 108 14 2 Preset diagram ...
Страница 125: ...AMT58x PN ProfiNET 109 14 3 Parking sensor diagram ...
Страница 126: ...AMT58x PN ProfiNET 110 14 4 Error diagram 14 4 1 Acknowledgment of acknowledgeable sensor error ...
Страница 127: ...AMT58x PN ProfiNET 111 14 4 2 Acknowledgment of not acknowledgeable sensor error ...
Страница 145: ......