AMT58x-CB CANopen®
22
1010-01 Store parameters
[Unsigned32, rw]
Use this object to save all parameters on non-volatile memory.
Write "save" (ASCII code in hexadecimal form) in the data bytes:
Master
Encoder
COB-ID
Cm
d
Index Sub
Data
bytes
600+ID 23 10 10 01 73 61 76 65
Encoder
Master (confirmation)
COB-ID
Cm
d
Index Sub
Data
bytes
580+ID 60 10 10 01 00 00 00 00
1011-01 Restore default parameters
[Unsig32, rw]
This object allows the operator to restore all parameters to default
values (default values are set at the factory by Datalogic Automation
engineers to allow the operator to run the device for standard
operation in a safe mode).
Write "load" (ASCII code in hexadecimal form) in the data bytes and
then issue a Reset node command:
Master
Encoder
COB-ID
Cmd Index Sub
Data
bytes
600+ID 23 11 10 01 6C 6F 61 64
Encoder
Master (confirmation)
COB-ID
Cmd Index Sub
Data
bytes
580+ID 60 11 10 01 00 00 00 00
Master
Encoder (Reset node)
COB-ID
Cmd Slave
ID
000 81 ID
Encoder
Master (Boot-up)
COB-ID
Cmd
700+ID 00
NOTE
Save default values using the store parameters function (see object
1010-01 Store parameters
).
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]